The K3 Series are for use in high temperature applications where the process temperatures may reach 538°C (1000°F) such as high temperature engineered polymers. The K Series utilizes standard melt pressure principles and construction, but uses a near incompressible NAK (Sodium Potassium) for pressure transmission.
The K Series strain sensing technology is bonded foil strain gage.
TECHNICAL DATA OF K3 NAK
Accuracy (1) | H <±0.25%FSO (100…1000 bar)
M <±0.5%FSO (35…1000 bar) |
Resolution | Infinite |
Measurement range | 0..35 a 0..1000bar
0..500 a 0..15000psi |
Maximum overpressure | 2 x FSO
1.5 x FSO over 700bar/10000psi |
Measurement principle | Strain gauge |
Power supply | 6..12Vdc (10Vdc typical) |
Bridge resistance |
350 Ohm
(550 Ohm below 100bar – 1500psi) |
Insulation resistance (at 50Vdc) | >1000 MOhm |
Output signal Full Scale FSO (tolerance ± 0;5% FSO) | 2.5 mV/V (option 2)
3.33 mV/V (option 3) |
Zero balance | ±5% |
Calibration signal | 80% FSO |
Compensated temperature range | 0…+100°C
32…212°F |
Maximum temperature range | -30…+120°C
-22…250°F |
Thermal drift in compesated range: Zero / Calibration / Sensibility | < 0.02% FSO/°C
< 0.01% FSO/°F |
Diaphragm maximum temperature | 538°C
1000°F |
Zero drift due to change in process temperature) | < 3,5 bar/100°C
< 28 psi/100°F |
Thermocouple (model K32) | STD : type “J” (isolated junction) |
Protection degree
(with 6-pole female connector) |
IP65 |
Electrical connections |
Conn. 6-pin VPT07RA10-6PT (PT02A-10-6P)
Conn.8-pin PC02E-12-8P |
FSO = Full Scale Output
(1) BFSL method (Best Fit Straight Line): includes combined effects of Non- Linearity, Hysteresis and Repeatability.