Mô tả
THÔNG SỐ KỸ THUẬT CỦA FFE200
Power supply | ADV200-4: 3 x 380Vac -15% … 500Vac +5%; 50-60 Hz ± 5% ADV200-4/4A-DC: 450…750Vdc; ADV200-6/6A-DC: 840 … 1120Vdc (5750 … 61320); 600 … 1120Vdc (≥ 71600). ADV200-6: 3 x 690Vac ±10%; 50-60 Hz ± 5% (5750 … 61320), 3 x 500…690Vac ±10%; 50-60 Hz ± 5% (71600 … 1.65MW) |
Power ratings | ADV200-4: from 0.75kW to 1.0MW ADV200-DC: from 18.5kW to 1.65MW ADV200-6: from 75kW to 1.65MW |
Maximum output voltage | 0,98 x Vin |
Maximum output frequency f2 | 500Hz (1007 … 72000), 200Hz (72500 … 1650kW) |
IGBT braking unit | Sizes 1007 … 5550: Internal (with external resistor); braking torque 150 % MAX Sizes ≥ 5750: External optional (BUy series) |
ADV200-4, ADV200-4-DC, ADV200-6-DC: | |
Overload | Heavy Duty: 160 % x In (1’ each 5‘), 200 % x In (for 3”). Light Duty: 110 % x In (1’ each 5‘). ADV200-6 (5750 … 6110) |
(for Synchronous motor) | Heavy Duty: 150 % x In (1’ each 5‘), 200 % x In (for 3”). Light Duty: n.d. ADV200-6 (72000 … 1.65MW) |
Heavy Duty: 160 % x In (1’ each 5‘), 200 % x In (for 3”). Light Duty: 110 % x In (for 60”). | |
ADV200-4, ADV200-4-DC, ADV200-6-DC | |
Heavy Duty: 150 % x In (1’ each 5‘), 180 % x In (for 0.5”). | |
Overload (for Asynchronous motor) | Light Duty: 110 % x In (1’ each 5‘). ADV200-6 (5750 … 6110) Heavy Duty: 136 % x In (for 60”), 183 % x In (for 0.5”). Light Duty: n.d. |
ADV200-6 (72000 … 1.65MW) | |
Heavy Duty: 150 % x In (for 60”), 180 % x In (for 0.5”). Light Duty: 110 % x In (for 60”). | |
Control mode | Open-loop vector control Vector control with feedback Open loop V/f and V/f with feedback |
Optional cards | Integration of up to 3 options onboard the drive “Safety STO” card compliant with SIL3 machine safety directive (for ADV200-…+SI models) |
Multi-language programming SW PLC | GF-eXpress (5 languages) PLC with advanced IEC61131-3 programming environment |
Rated protection | IP20-rated protection (IP00 size 7 and parallel) |
Fieldbus management | DeviceNet, CANopen®, Modbus RTU, EtherCAT, GDnet, PROFIBUS, Industrial Ethernet (1), PROFINET |
Precision | Control mode | Speed control precision (2) | Control Range | |
Asynch. | FOC with feedback | ± 0.01% motor speed rating | 1 : 1000 | |
Open-loop FOC | ± 30% motor slip rating | 1 : 100 | ||
V/F | ± 60% motor slip rating | 1 : 30 | ||
Synch. | FOC with feedback | ± 0.01% motor speed rating | 1 : 1500 | |
Open-loop FOC | ± 0,1% motor speed rating | 1 : 20 |
Standard supply configuration | Programming keypad
Regulation | Integrated KB_ADV • 2 bipolar analog inputs (Voltage/Current) • 2 bipolar analog outputs (1: Voltage/Current, 1: Voltage) • 6 digital inputs (PNP/NPN) • 2 digital outputs (PNP/NPN) • 2 relay outputs, single contact • RS485 serial line (Modbus RTU) |
Power
Reference resolution | • Integrated choke DC side (up to 132 kW) • Integrated mains filter • Integrated dynamic braking module (up to 55kW) | |
• Digital = 15bit + sign • Analog input = 11-bit + sign • Analog output = 11-bit + sign | ||
Immunity/Emissions
Safety standards | CEE – EN 61800-3 EN 50178, EN 61800-5-1, UL508C, UL840 degree of pollution 2 STO (Safe Torque Off): IEC 61508 SIL 3, EN 954-1 Cat. 3 EN 61508 and EN 61800-5-2 | |
Environmental conditions | Ambient temperature | -10°C … +40°C (+14°F …+104°F), +40°C…+50°C (+104°F…+122°F) with derating |
Altitude | Max 4000 m. (up to 1000 m without derating) | |
Markings |
| Complies with the EC directive concerning low voltage equipment (Directives LVD 2014/35/EU, EMC 2014/30/EU, RoHs 2011/65/EU) |
| UL and cULus, Complies with directives for the American and Canadian markets (with power supply ≤600Vac) |
Đánh giá
Chưa có đánh giá nào.