Datasheet excerpt: Technical data of UC4000-L2-E5-V15 Pepperl Fuchs
| Product Description |
|---|
| Single head system |
| General specifications | ||
|---|---|---|
| Sensing range | 200 … 4000 mm | |
| Adjustment range | 240 … 4000 mm | |
| Dead band | 0 … 200 mm | |
| Standard target plate | 100 mm x 100 mm | |
| Transducer frequency | approx. 85 kHz | |
| Nominal ratings | ||
| Response delay | minimum: 110 ms factory setting: 280 ms | |
| Time delay before availability | ≤ 1600 ms | |
| Indicators/operating means | ||
| LED green | Operating display | |
| LED yellow | switching state | |
| LED red | error | |
| Electrical specifications UC4000-L2-E5-V15 | ||
| Operating voltage | 10 … 30 V DC , ripple 10 %SS | |
| No-load supply current | ≤ 50 mA | |
| Interface | ||
| Interface type | Serial interface (programming adapter required) 9600 BPS, no parity, 8 data bits, 1 stop bit | |
| Input/Output | ||
| Input/output type | 1 synchronization connection, bidirectional | |
| 0 Level | 0 … 1 V | |
| 1 Level | 4 V … UB | |
| Input impedance | > 12 kΩ | |
| Output rated operating current | < 12 mA | |
| Pulse length | 0.5 … 300 ms (level 1) | |
| Pulse interval | ≥ 62.5 ms (level 0) | |
| Synchronization frequency | ||
| Common mode operation | ≤ 16 Hz | |
| Multiplex operation | ≤ 17 Hz / n , n = number of sensors , n ≤ 10 (factory setting: n = 5 ) | |
Input | ||
| Input type | 1 program input | |
| Level (switch point 1) | 0 … 1 V | |
| Level (switch point 2) | 4 V … UB | |
| Input impedance | > 10 kΩ | |
| Pulse length | 2 … 10 s | |
| Output | ||
| Output type | 1 switching output E5, PNP NO/NC, programmable | |
| Rated operating current | 200 mA , short-circuit/overload protected | |
| Voltage drop | ≤ 2 V | |
| Repeat accuracy | ≤ 0.1 % of full-scale value | |
| Switching frequency | ≤ 2.8 Hz | |
| Range hysteresis | programmable , preset to 1 mm | |
| Temperature influence | < 1.5 % of full-scale value | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector plug M12 x 1 , 5-pin | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | PA-GF35 | |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam | |
| Mass | 120 g | |
| Factory settings | ||
| Output | near switch point: 240 mm far switch point: 4000 mm output function: Window mode output behavior: NO contact | |
| Beam width | wide | |
| Evaluation procedure | averaging (MxN) M = 5 N = 2 | |
| General information | ||
| Supplementary information | Switch settings of the external programming adapter: “output load”: pull-down “output logic”: inv | |
Classifications UC4000-L2-E5-V15
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27272803 |
| ECLASS 10.0.1 | 27272803 |
| ECLASS 9.0 | 27272803 |
| ECLASS 8.0 | 27272803 |
| ECLASS 5.1 | 27272803 |
| ETIM 8.0 | EC001849 |
| ETIM 7.0 | EC001849 |
| ETIM 6.0 | EC001849 |
| ETIM 5.0 | EC001849 |
| UNSPSC 12.1 | 41111960 |




Đánh giá