Mô tả
Thông số kỹ thuật của cảm biến OMT100-R100-2EP-IO-V31
Product Description | ||
---|---|---|
Measurement to object, 100 mm detection range, red light, measured value via IO-Link, 2 x push-pull output, M8 plug |
General specifications | ||
---|---|---|
Measurement range | 40 … 100 mm | |
Reference target | standard white, 100 mm x 100 mm | |
Light source | LED | |
Light type | modulated visible red light | |
LED risk group labelling | exempt group | |
Angle deviation | max. +/- 1.5 ° | |
Diameter of the light spot | approx. 8 mm at a distance of 100 mm | |
Angle of divergence | 4 ° | |
Ambient light limit | EN 60947-5-2 : 30000 Lux | |
Resolution | 0.1 mm | |
Functional safety related parameters | ||
MTTFd | 600 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: constantly on – power on flashing (4Hz) – short circuit flashing with short break (1 Hz) – IO-Link mode | |
Function indicator | LED yellow: constantly on – switch output active constantly off – switch output inactive | |
Control elements | Teach-In key | |
Control elements | 5-step rotary switch for operating modes selection | |
Electrical specifications | ||
Operating voltage | 10 … 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | < 25 mA at 24 V supply voltage | |
Protection class | III | |
Interface | ||
Interface type | IO-Link ( via C/Q = pin 4 ) | |
IO-Link revision | 1.1 | |
Device profile | Smart Sensor | |
Device ID | 0x110903 (1116419) | |
Transfer rate | COM2 (38.4 kBaud) | |
Min. cycle time | 3 ms | |
Process data width | Process data input 3 Byte Process data output 2 Bit | |
SIO mode support | yes | |
Compatible master port type | A | |
Output | ||
Switching type | The default setting is: C/Q – Pin4: NPN normally open, PNP normally closed, IO-Link Q2 – Pin2: NPN normally-open, PNP normally-closed | |
Signal output | 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, overvoltage protected | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Usage category | DC-12 and DC-13 | |
Voltage drop | ≤ 1.5 V DC | |
Response time | 2 ms | |
Conformity | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
Approvals and certificates | ||
EAC conformity | TR CU 020/2011 | |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
Measurement accuracy | ||
Temperature drift | 0.03 %/K | |
Warm up time | 5 min | |
Repeat accuracy | ≤ 0.5 % | |
Linearity error | ± 0,75 % | |
Ambient conditions | ||
Ambient temperature | 10 … 60 °C (50 … 140 °F) | |
Storage temperature | -40 … 70 °C (-40 … 158 °F) | |
Mechanical specifications | ||
Housing width | 11 mm | |
Housing height | 44.5 mm | |
Housing depth | 21.5 mm | |
Degree of protection | IP67 / IP69 / IP69K | |
Connection | M8 x 1 connector, 4-pin | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 10 g |
Phân loại
System | Classcode |
---|---|
ECLASS 11.0 | 27270903 |
ECLASS 10.0.1 | 27270903 |
ECLASS 9.0 | 27270903 |
ECLASS 8.0 | 27270903 |
ECLASS 5.1 | 27270903 |
ETIM 8.0 | EC001821 |
ETIM 7.0 | EC001821 |
ETIM 6.0 | EC001821 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
Đánh giá
Chưa có đánh giá nào.