Description
Datasheet excerpt: Technical data of VDM100-150-P/G2
Product Description | ||
---|---|---|
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, PROFIBUS, M12 plug |
General specifications | ||
---|---|---|
Measurement range | 0.3 … 150 m | |
Reference target | Foil reflector 500 mm x 500 mm | |
Light source | laser diode | |
Laser nominal ratings | ||
Note | VISIBLE AND INVISIBLE LASER RADIATION , DO NOT STARE INTO BEAM | |
Laser class | Measurement laser: 1 Alignment laser: 2 | |
Wave length | Measurement laser: 905 nm Alignment laser: 660 nm | |
Beam divergence | Measurement laser: 2 mrad Alignment laser: 1 mrad | |
Pulse length | Measurement laser: 4 ns | |
Repetition rate | Measurement laser: 20 kHz | |
Maximum optical power output | Alignment laser: 0.6 mW | |
max. pulse energy | Measurement laser: 12 nJ | |
Measuring method | Pulse Ranging Technology (PRT) | |
Max. Motion velocity | 15 m/s | |
Alignment aid | Laser pointer | |
Life span | > 100000 h | |
Diameter of the light spot | < 35 cm at 150 m | |
Ambient light limit | > 100000 Lux | |
Resolution | 0.1 mm , adjustable | |
Temperature influence | 0.03 mm/K | |
Functional safety related parameters | ||
MTTFd | 89 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Function indicator | 4 LEDs | |
Control elements | Control panel (4 membrane keys) for setting parameters | |
Parameterization indicator | Illuminated display for displaying measured values and parameterization | |
Electrical specifications | ||
Operating voltage | 18 … 30 V DC | |
No-load supply current | 250 mA (18 V) … 150 mA (30 V) | |
Protection class | III (operating voltage 50 V) | |
Time delay before availability | < 10 s | |
Interface | ||
Interface type | PROFIBUS DP acc. to EN 50170 | |
Transfer rate | 9.6 kbit/s … 12 Mbit/s , adjustable | |
Input/Output | ||
Input/output type | 2 PNP inputs/outputs, independent configuration, short-circuit protected, reverse polarity protected | |
Input | ||
Switching threshold | low: Ue < 6 V, high: Ue > 16 V | |
Output | ||
Switching threshold | low: Ua < 1 V, high: Ua > Ub – 1 V | |
Switching current | 200 mA per output | |
Conformity | ||
Product standard | EN 60947-5-2 | |
Laser safety | IEC 60825-1:2007 | |
Measurement accuracy | ||
Measured value output | 1 ms | |
Average data age | 3 ms , 6 ms , 12 ms , 25 ms , 50 ms , adjustable | |
Offset | max. 2 mm (between two devices) | |
Absolute accuracy | ± 2.5 mm (> 3 m); ± 3.5 mm (0.3 m to 3 m) | |
Repeat accuracy | < 0.5 mm | |
Approvals and certificates | ||
UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
FDA approval | IEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 | |
Ambient conditions | ||
Ambient temperature | -10 … 50 °C (14 … 122 °F) | |
Storage temperature | -20 … 70 °C (-4 … 158 °F) | |
Relative humidity | 95 % , no moisture condensation | |
Mechanical specifications | ||
Housing width | 140 mm | |
Housing height | 100 mm | |
Degree of protection | IP65 | |
Connection | 4-pin, M12x1 connector, standard (supply) , 5-pin, M12x1 connector, B-coded (Bus In) , 5-pin, M12x1 socket, B-coded (Bus Out) , 8-pin, M12x1 connector, service | |
Material | ||
Housing | ABS / PC | |
Optical face | PMMA , hard coated | |
Mass | approx. 700 g |
Classifications
System | Classcode |
---|---|
ECLASS 11.0 | 27270801 |
ECLASS 10.0.1 | 27270801 |
ECLASS 9.0 | 27270801 |
ECLASS 8.0 | 27270801 |
ECLASS 5.1 | 27270801 |
ETIM 8.0 | EC001825 |
ETIM 7.0 | EC001825 |
ETIM 6.0 | EC001825 |
ETIM 5.0 | EC001825 |
Reviews
There are no reviews yet.