Description
| TECHNICAL DATA | |||
| Clamping force output (CF) | Mold protection output (MP) | Cavity pressure profile output (CPP) | |
| Linearity | < ± 0.02% FS | < ± 0.02% FS | < ± 0.02% FS |
| Accuracy at room temperature (1) | < ± 0.2% FS | < ± 1% typ. (< ± 2% max.) | < ± 1% typ. (< ± 2% max.) |
| Signal input range (FS) | 0.1…3.00 mV/V (100…3000με) | 0.02…0.10 mV/V (20…100με) | 0.02…0.10 mV/V (20…100με) |
| Output resolution | 16-Bit | 16-Bit | 16-Bit |
| Sampling rate | 1 kHz | 1 kHz | 1 kHz |
| Low-pass filter | 100 Hz | 100 Hz | 100 Hz |
| Case material | Aluminum anodized | ||
| Reset time | see order code | ||
| Reset voltage | 12…36 VDC | ||
| Supply voltage | 12…36 VDC | ||
| Power consumption | 0.6W | ||
| Allowed load | ≥5 kΩ | ≥5 kΩ | ≥5 kΩ |
| Operating temperature range | -40…+85°C | ||
| Storage temperature range | -40…+100°C | ||
| Temperature effects | ± 0.01% FS/°C | ± 0.02% FS/°C | ± 0.02% FS/°C |
| Weight | ~160 g | ||
| Protection class | IP65 | ||
| Output short circuit protection | Yes | ||
| Reverse polarity protection | Yes | ||
| Dielectric strenght (2) | 250V | ||
| EC Conformity A | According to Directive 2014/30/EU | ||
| (1) incl. Non-linearity, Hysteresis, Repeatability, Zero-offset and Span-offset | |||
| (2) Uses 50V 2J Voltage suppressor | |||
| The three output ranges are from 0 up to ±12 V. The amplifier has an integrated sensor cable breakage detection. In the event of an interruption in one or more sensor lines, the output voltage increases or decreases to a value ±11.5V … ±12V. In order to properly use the cable breakage detection it is suggested to use the amplifier only in the range ±10.0V and to make sure that the amplifier is reset after every machine cycle. | |||