Description
Datasheet excerpt: Technical data of UC250-F77-EP-IO-V31
| Product Description | ||
|---|---|---|
| Single head system | ||
| General specifications | ||
|---|---|---|
| Sensing range | 20 … 250 mm | |
| Adjustment range | 25 … 250 mm | |
| Dead band | 0 … 20 mm | |
| Standard target plate | 10 mm x 10 mm | |
| Transducer frequency | approx. 400 kHz | |
| Response delay | minimum : 8 ms factory setting: 29 ms | |
| Sensor cycle time | ≥ 8 ms (factory setting) ; programmable to 60 s | |
| Memory | ||
| Non-volatile memory | EEPROM | |
| Write cycles | 300000 | |
| Indicators/operating means | ||
| LED green | solid: Power on flashing: Standby mode or IO-Link communication | |
| LED yellow | solid: object in evaluation range flashing: switch point programming, object detected | |
| LED red | solid: error flashing: switch point programming, object not detected | |
| Electrical specifications | ||
| Operating voltage | 10 … 30 V DC , ripple 10 %SS | |
| No-load supply current | ≤ 40 mA | |
| Power consumption | ≤ 400 mW | |
| Time delay before availability | ≤ 300 ms | |
| Interface | ||
| Interface type | IO-Link (via C/Q = Pin 4) | |
| Device profile | Smart Sensor | |
| Transfer rate | COM 2 (38.4 kBaud) | |
| IO-Link Revision | 1.1 | |
| Min. cycle time | 2.3 ms | |
| Process data width | 16 bit | |
| SIO mode support | yes | |
| Device ID | 0x300300 (3146496) | |
| Compatible master port type | A | |
| Input/Output | ||
| Input/output type | 1 synchronization connection, bidirectional | |
| 0 Level | 0 … 1 V | |
| 1 Level | 2.5 V … UB | |
| Input impedance | > 22 kΩ | |
| Output rated operating current | current source < 2.5 mA | |
| Pulse length | ≥ 1 ms with external control, low active | |
| Synchronization frequency | ||
| Common mode operation | ≤ 141 Hz | |
| Multiplex operation | ≤ 141 Hz / n , n = number of sensors , n ≤ 10 | |
| Output | ||
| Output type | 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected | |
| Rated operating current | 100 mA , short-circuit/overload protected | |
| Voltage drop | ≤ 2.5 V | |
| Repeat accuracy | ≤ ± 0.1 % of full-scale value | |
| Switching frequency | factory setting: 20 Hz programmable max. 45 Hz | |
| Range hysteresis | 1 % of the adjusted operating range (default settings), programmable , min. 1 mm | |
| Temperature influence | ≤ ± 0.75 % of the end value (with temperature compensation) from 10 minutes after switching on the sensor ; 0,17 %/K (without temperature compensation) | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector plug M8 x 1 , 4-pin | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | Polycarbonate | |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam | |
| Installation position | any position | |
| Mass | 9 g | |
| Tightening torque, fastening screws | max. 0.2 Nm | |
| Factory settings | ||
| Output | near switch point: 25 mm far switch point: 250 mm Output mode: Window mode Output logic: normally open | |
| Beam width | wide | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27272803 |
| ECLASS 10.0.1 | 27272803 |
| ECLASS 9.0 | 27272803 |
| ECLASS 8.0 | 27272803 |
| ECLASS 5.1 | 27272803 |
| ETIM 8.0 | EC001849 |
| ETIM 7.0 | EC001849 |
| ETIM 6.0 | EC001849 |
| ETIM 5.0 | EC001849 |
| UNSPSC 12.1 | 41111960 |




Reviews
There are no reviews yet.