Description
Datasheet excerpt: Technical data of UBE1000-18GM40-SE2-V1
| Product Description | ||
|---|---|---|
| Single head system | ||
| General specifications | ||
|---|---|---|
| Sensing range | 15 … 1000 mm | |
| Standard target plate | 100 mm x 100 mm | |
| Transducer frequency | approx. 255 kHz | |
| Indicators/operating means | ||
| LED green | Power on | |
| LED yellow | switching state | |
| LED red | error, object uncertain | |
| Electrical specifications | ||
| Operating voltage | 10 … 30 V DC , ripple 10 %SS | |
| No-load supply current | ≤ 20 mA | |
| Input | ||
| Input type | 1 program input free air path: -UB … +1 V, object: +6 V … +UB input impedance: > 4,7 kΩ program pulse: ≥ 1 s | |
| Output | ||
| Output type | PNP, NO | |
| Rated operating current | 200 mA , short-circuit/overload protected | |
| Voltage drop | ≤ 3 V | |
| Switch-on delay | < 5 ms | |
| Switching frequency | ≤ 100 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | brass, nickel-plated | |
| Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT | |
| Mass | 25 g | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27272801 |
| ECLASS 10.0.1 | 27272801 |
| ECLASS 9.0 | 27272801 |
| ECLASS 8.0 | 27272801 |
| ECLASS 5.1 | 27272801 |
| ETIM 8.0 | EC001847 |
| ETIM 7.0 | EC001847 |
| ETIM 6.0 | EC001847 |
| ETIM 5.0 | EC001847 |




Reviews