Description
Datasheet excerpt: Technical data of UB1000-18GM75-E5-V15
| Product Description | ||
|---|---|---|
| Single head system | ||
| General specifications | ||
|---|---|---|
| Sensing range | 70 … 1000 mm | |
| Adjustment range | 90 … 1000 mm | |
| Dead band | 0 … 70 mm | |
| Standard target plate | 100 mm x 100 mm | |
| Transducer frequency | approx. 255 kHz | |
| Response delay | approx. 125 ms | |
| Indicators/operating means | ||
| LED yellow | indication of the switching state flashing: program function object detected | |
| LED red | solid red: Error red, flashing: program function, object not detected | |
| Electrical specifications | ||
| Operating voltage | 10 … 30 V DC , ripple 10 %SS | |
| No-load supply current | ≤ 50 mA | |
| Input/Output | ||
| Synchronization | 1 synchronous connection, bi-directional 0-level: -UB…+1 V 1-level: +4 V…+UB input impedance: > 12 kΩ synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms | |
| Synchronization frequency | ||
| Common mode operation | max. 40 Hz | |
| Multiplex operation | ≤ 40 Hz / n, n = number of sensors, n ≤ 5 | |
| Input | ||
| Input type | 1 program input, operating range 1: -UB … +1 V, operating range 2: +4 V … +UB input impedance: > 4.7 kΩ; program pulse: ≥ 1 s | |
| Output | ||
| Output type | 1 switch output PNP Normally open/closed , programmable | |
| Rated operating current | 200 mA , short-circuit/overload protected | |
| Voltage drop | ≤ 3 V | |
| Repeat accuracy | ≤ 1 % | |
| Switching frequency | max. 3 Hz | |
| Range hysteresis | 1 % of the set operating distance | |
| Temperature influence | ± 1.5 % of full-scale value | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector plug M12 x 1 , 5-pin | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | brass, nickel-plated | |
| Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT | |
| Mass | 60 g | |
| Factory settings | ||
| Output | Switch point A1: 90 mm Switch point A2: 1000 mm output function: Window mode output behavior: NO contact | |
| Beam width | wide | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27272803 |
| ECLASS 10.0.1 | 27272803 |
| ECLASS 9.0 | 27272803 |
| ECLASS 8.0 | 27272803 |
| ECLASS 5.1 | 27272803 |
| ETIM 8.0 | EC001849 |
| ETIM 7.0 | EC001849 |
| ETIM 6.0 | EC001849 |
| ETIM 5.0 | EC001849 |