Description
| TECHNICAL DATA OF TU | |
| Accuracy | 0,2% |
| Nominal full scale load (Ln) | 50…1000 kg |
| Nominal output at FSO | 2mV/V |
| Output tolerance at Ln | <± 0,2% FSO |
| Combined errors: Non linearity Histeresis, Repeatibility | < ± 0,2% FSO |
| Creep (after 30 min. at Ln) | < ± 0,06% FSO |
| Zero load out of balance signal | < ± 1% FSO |
| Thermal drift in Sensitivity compensated Zero range Calibration | < ± 0,01% FSO°C < ± 0,01% FSO°C – |
| Nominal input resistance | 350 Ohm |
| Nominal output resistance | 350 Ohm |
| Isolation resistance | > 10 GOhm |
| Nominal supply voltage | 10 V |
| Maximum supply voltage | 15 V |
| Compensated temperature range | -10…+50°C |
| Maximum temperature range | -20…+60°C |
| Storage temperature range | -30…+80°C |
| Permitted static load | 130% Ln |
| Permitted dinamic load | 100% Ln |
| Maximum applicable load | 150% Ln |
| Rupture load | > 300% Ln |
| Maximum elastic deformation at Ln | < 0,2 mm |
| Grade of protection (DIN40050) | IP67 |
| Electr. connections screened cable | 4×0,25 / 5 m. |
| Elastic element material | Stainless steel |