Description
Datasheet excerpt: Technical data of PHA200-F200-R3
| Product Description | ||
|---|---|---|
| Precision positioning on hole in the 70 mm x 70 mm housing | ||
| General specifications | ||
|---|---|---|
| Light source | LED | |
| Light type | Integrated LED lightning (infrared) | |
| Object size | Hole diameter 13 mm | |
| Response delay | 100 ms | |
| Read distance | 200 mm | |
| Depth of focus | ± 50 mm | |
| Capture range | max. 120 mm x 100 mm | |
| Nominal ratings | ||
| Camera | ||
| Type | CMOS , Global shutter | |
| Number of pixels | 752 x 480 pixels | |
| Gray scale | 256 | |
| Functional safety related parameters | ||
| MTTFd | 85 a | |
| Mission Time (TM) | 10 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED green: Ready for operation | |
| Function indicator | 4 x LED yellow: +X, -X, +Y, -Y | |
| Electrical specifications | ||
| Operating voltage | 24 V DC ± 15% , PELV | |
| No-load supply current | max. 250 mA | |
| Power consumption | 6 W | |
| Interface | ||
| Interface type | serial RS-422 | |
| Transfer rate | 9600 … 230400 Bit/s | |
| Interface 1 | ||
| Interface type | Ethernet | |
| Protocol | TCP/IP | |
| Transfer rate | 100 MBit/s | |
| Cable length | max. 30 m | |
| Input | ||
| Input voltage | to be applied externally 24 V ± 15% PELV | |
| Number/Type | Cycle stop, relative stroke | |
| Input current | 1.6 mA at 24 V | |
| Switching threshold | low: < 10 V, high: > 15 V | |
| Cable length | max. 30 m | |
| Output | ||
| Switching type | PNP , short-circuit/overload protected | |
| Signal output | +X, -X, +Y, -Y | |
| Switching voltage | 24 V | |
| Switching current | max. 100 mA each output | |
| Cable length | max. 30 m | |
| Conformity | ||
| Shock resistance | EN 60068-2-27:2009 | |
| Vibration resistance | EN 60068-2-6:2008 | |
| Emitted interference | EN 61000-6-4:2007+A1:2011 | |
| Noise immunity | EN 61326-1:2013 | |
| Photobiological safety | exempt group according EN 62471:2008 | |
| Approvals and certificates | ||
| CE conformity | CE | |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Operating temperature | 0 … 60 °C (32 … 140 °F) , (noncondensing; prevent icing on the lens!) | |
| Storage temperature | -20 … 85 °C (-4 … 185 °F) | |
| Relative humidity | 90 % , noncondensing | |
| Shock resistance | < 50 g | |
| Vibration resistance | < 3 G , 11 … 200 Hz | |
| Mechanical specifications | ||
| Housing width | 70 mm | |
| Housing height | 70 mm | |
| Housing depth | 50 mm | |
| Degree of protection | IP67 | |
| Connection | 8-pin, M12x1 connector, standard (supply+IO) , 5-pin, M12x1 socket, A-coded ( RS-422 ) , 4-pin, M12x1 socket, standard (LAN) | |
| Material | ||
| Housing | PC/ABS | |
| Optical face | Plastic pane | |
| Installation | 4 x M6 threading | |
| Mass | approx. 160 g | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27310101 |
| ECLASS 10.0.1 | 27310101 |
| ECLASS 9.0 | 27310101 |
| ECLASS 8.0 | 27310101 |
| ECLASS 5.1 | 27310101 |
| ETIM 8.0 | EC001852 |
| ETIM 7.0 | EC001852 |
| ETIM 6.0 | EC001852 |
| ETIM 5.0 | EC001852 |




Reviews
There are no reviews yet.