Description
Datasheet excerpt: Technical data of OMT550-R200-IEP-IO-V1
| Product Description | ||
|---|---|---|
| Distance sensor | ||
| General specifications | ||
|---|---|---|
| Measurement range | 100 … 550 mm | |
| Reference target | standard white, 100 mm x 100 mm | |
| Light source | LED | |
| Light type | modulated visible red light | |
| LED risk group labelling | exempt group | |
| Angle deviation | max. +/- 1.5 ° | |
| Diameter of the light spot | approx. 20 mm at a distance of 550 mm | |
| Angle of divergence | 2.5 ° | |
| Ambient light limit | EN 60947-5-2 : 45000 Lux | |
| Resolution | 0.1 mm | |
| Functional safety related parameters | ||
| MTTFd | 520 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED green: constantly on – power on flashing (4Hz) – short circuit flashing with short break (1 Hz) – IO-Link mode | |
| Function indicator | LED yellow: constantly on – switch output active constantly off – switch output inactive | |
| Control elements | Teach-In key | |
| Control elements | 5-step rotary switch for operating modes selection | |
| Electrical specifications | ||
| Operating voltage | 18 … 30 V DC | |
| Ripple | max. 10 % | |
| No-load supply current | < 25 mA at 24 V supply voltage | |
| Protection class | III | |
| Interface | ||
| Interface type | IO-Link ( via C/Q = pin 4 ) | |
| Device profile | Identification and diagnosis Smart Sensor type 0/type 3.3 | |
| Transfer rate | COM 2 (38.4 kBaud) | |
| IO-Link Revision | 1.1 | |
| Min. cycle time | 3 ms | |
| Process data width | Process data input 4 byte Process data output 2 bits | |
| SIO mode support | yes | |
| Device ID | 0x111902 (1120514) | |
| Compatible master port type | A | |
| Output | ||
| Switching type | The default setting is: C/Q – Pin4: NPN normally open, PNP normally closed, IO-Link I—Pin2: analog output 4…20 mA | |
| Signal output | 1 push-pull output , 1 analog output , short-circuit-proof, reverse polarity protection, surge-proof | |
| Switching voltage | max. 30 V DC | |
| Switching current | max. 100 mA , resistive load | |
| Usage category | DC-12 and DC-13 | |
| Voltage drop | ≤ 1.5 V DC | |
| Response time | 2 ms , see table 1 | |
| Analog output | ||
| Output type | 1 current output: 4 … 20 mA | |
| Load resistor | > 1 kΩ voltage output ; ≤ 470 Ω current output | |
| Recovery time | 2 ms | |
| Conformity | ||
| Communication interface | IEC 61131-9 | |
| Product standard | EN 60947-5-2 | |
| Measurement accuracy | ||
| Temperature drift | 0.05 %/K | |
| Warm up time | 5 min | |
| Repeat accuracy | ≤ 1 % , see table 1 | |
| Linearity error | 0.75 % | |
| Approvals and certificates | ||
| UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | 10 … 50 °C (50 … 122 °F) | |
| Storage temperature | -40 … 70 °C (-40 … 158 °F) | |
| Mechanical specifications | ||
| Housing width | 15 mm | |
| Housing height | 50.6 mm | |
| Housing depth | 41.7 mm | |
| Degree of protection | IP67 / IP69 / IP69K | |
| Connection | 4-pin, M12 x 1 connector, 90° rotatable | |
| Material | ||
| Housing | PC (Polycarbonate) | |
| Optical face | PMMA | |
| Mass | approx. 37 g | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27270801 |
| ECLASS 10.0.1 | 27270801 |
| ECLASS 9.0 | 27270801 |
| ECLASS 8.0 | 27270801 |
| ECLASS 5.1 | 27270801 |
| ETIM 8.0 | EC001825 |
| ETIM 7.0 | EC001825 |
| ETIM 6.0 | EC001825 |
| ETIM 5.0 | EC001825 |
| UNSPSC 12.1 | 41111613 |




Reviews