Description
Datasheet excerpt: Technical data of OMT550-R200-IEP-IO-V1
Product Description | ||
---|---|---|
Distance sensor |
General specifications | ||
---|---|---|
Measurement range | 100 … 550 mm | |
Reference target | standard white, 100 mm x 100 mm | |
Light source | LED | |
Light type | modulated visible red light | |
LED risk group labelling | exempt group | |
Angle deviation | max. +/- 1.5 ° | |
Diameter of the light spot | approx. 20 mm at a distance of 550 mm | |
Angle of divergence | 2.5 ° | |
Ambient light limit | EN 60947-5-2 : 45000 Lux | |
Resolution | 0.1 mm | |
Functional safety related parameters | ||
MTTFd | 520 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: constantly on – power on flashing (4Hz) – short circuit flashing with short break (1 Hz) – IO-Link mode | |
Function indicator | LED yellow: constantly on – switch output active constantly off – switch output inactive | |
Control elements | Teach-In key | |
Control elements | 5-step rotary switch for operating modes selection | |
Electrical specifications | ||
Operating voltage | 18 … 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | < 25 mA at 24 V supply voltage | |
Protection class | III | |
Interface | ||
Interface type | IO-Link ( via C/Q = pin 4 ) | |
Device profile | Identification and diagnosis Smart Sensor type 0/type 3.3 | |
Transfer rate | COM 2 (38.4 kBaud) | |
IO-Link Revision | 1.1 | |
Min. cycle time | 3 ms | |
Process data width | Process data input 4 byte Process data output 2 bits | |
SIO mode support | yes | |
Device ID | 0x111902 (1120514) | |
Compatible master port type | A | |
Output | ||
Switching type | The default setting is: C/Q – Pin4: NPN normally open, PNP normally closed, IO-Link I—Pin2: analog output 4…20 mA | |
Signal output | 1 push-pull output , 1 analog output , short-circuit-proof, reverse polarity protection, surge-proof | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Usage category | DC-12 and DC-13 | |
Voltage drop | ≤ 1.5 V DC | |
Response time | 2 ms , see table 1 | |
Analog output | ||
Output type | 1 current output: 4 … 20 mA | |
Load resistor | > 1 kΩ voltage output ; ≤ 470 Ω current output | |
Recovery time | 2 ms | |
Conformity | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
Measurement accuracy | ||
Temperature drift | 0.05 %/K | |
Warm up time | 5 min | |
Repeat accuracy | ≤ 1 % , see table 1 | |
Linearity error | 0.75 % | |
Approvals and certificates | ||
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | 10 … 50 °C (50 … 122 °F) | |
Storage temperature | -40 … 70 °C (-40 … 158 °F) | |
Mechanical specifications | ||
Housing width | 15 mm | |
Housing height | 50.6 mm | |
Housing depth | 41.7 mm | |
Degree of protection | IP67 / IP69 / IP69K | |
Connection | 4-pin, M12 x 1 connector, 90° rotatable | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 37 g |
Classifications
System | Classcode |
---|---|
ECLASS 11.0 | 27270801 |
ECLASS 10.0.1 | 27270801 |
ECLASS 9.0 | 27270801 |
ECLASS 8.0 | 27270801 |
ECLASS 5.1 | 27270801 |
ETIM 8.0 | EC001825 |
ETIM 7.0 | EC001825 |
ETIM 6.0 | EC001825 |
ETIM 5.0 | EC001825 |
UNSPSC 12.1 | 41111613 |
Reviews