Datasheet excerpt: Technical data of MMB60-12GH50-E2-V1
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 60 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Actuating element | magnetic | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 … 30 V DC | |
| Switching frequency | 5000 Hz | |
| Hysteresis | 1 … 10 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | ≤ 2.5 V DC | |
| Operating current | ≤ 200 mA | |
| Current consumption | < 10 mA | |
| Indicators/operating means | ||
| Operation indicator | 4-way LED Yellow: output | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 … 75 °C (-13 … 167 °F) | |
| Mechanical specifications | ||
| Connection type | V1 connector (M12 x 1), 4-pin | |
| Housing material | stainless steel V4A | |
| Sensing face | stainless steel V4A | |
| Housing diameter | 12 mm | |
| Degree of protection | IP65 / IP67 / | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27270104 |
| ECLASS 10.0.1 | 27270104 |
| ECLASS 9.0 | 27270104 |
| ECLASS 8.0 | 27270104 |
| ECLASS 5.1 | 27270104 |
| ETIM 8.0 | EC002544 |
| ETIM 7.0 | EC002544 |
| ETIM 6.0 | EC002544 |
| ETIM 5.0 | EC002544 |
| UNSPSC 12.1 | 39121550 |