The fluid-filled system assures the temperature stability. The phisical quantity is transformed in a electrical mea- sure by means the thick film strain-gauge technology. The SIL2 certified version makes the product suitable for use in the Functional Safety applications, particularly in the process plants for the production of polymers, where it is an essential requirement.
TECHNICAL DATA OF ME SIL2
Accuracy (1) | H <±0.25%FS (100…2000 bar) M <±0.5%FS (17…2000 bar) |
Resolution | Infinite |
Measurement range | 0..17 to 0..2000bar 0..250 to 0..30000psi |
Maximum overpressure (without degra- ding performances) | 2 x FS 1.5 x FS above 1000bar/15000psi |
Measurement principle | Extensimetric thick film |
Power supply | 10…30Vdc |
Maximum current absorption | 32mA |
Insulation resistance (at 50Vdc) | >1000 MOhm |
Output signal Full Scale (FS) | 20mA |
Zero balance (tollerance ± 0.25% FS) | 4mA |
Zero signals adjustment (tollerance ± 0.25% FS) | “Autozero” function |
Span adjustment within ± 5% FS | See Manual |
Maximum allowed load | See diagram |
Response time (10…90% FS) | ~ 1ms |
Output noise (RMS 10-400Hz) | < 0.025% FS |
Calibration signal | 80% FS |
Output short circuit ingress and reverse polarity protection | YES |
Compensed temperature range | 0…+85°C |
Operating temperature range | -30…+105°C |
Storage temperature range | -40…+125°C |
Thermal drift in compesated range: Zero / Calibration / Sensibility | < 0.02% FS/°C |
Diaphragm maximum temperature | 400°C / 750°F |
Zero drift due to change in process tem- perature (zero) | < 0.02 bar/°C |
Zero drift temperature for Autocompensated version (SP) within the temperature range 20°C-400°C inclusive the drift temperature of the housing | < 0.003 bar/°C 100 ≤ p < 500 bar 0.0014 %FS/°C p ≥ 500 bar |
Standard material in contact with process medium | Diaphragm: • 15-5 PH with GTP+ coating • 17-7 PH corrugated diaphragm with GTP+ coating for ranges <100 bar (1500psi) Stem: • 17-4 PH |
Thermocouple (model ME2) | STD: type “J” (isolated junction) |
Protection degree (with 6-pole female connector CON300) | IP66 |
SIL2 certification | IEC/EN 62061 IEC 61508 |
FS = Full scale output : (1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability (according to IEC 62828-2).