Description
Datasheet excerpt: Technical data of MB60-12GM50-E2
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 60 mm | |
| Installation | flush in non-magnetic metal | |
| Output polarity | DC | |
| Assured operating distance | 10 … 48.6 mm | |
| Nominal ratings | ||
| Operating voltage | 10 … 30 V | |
| Switching frequency | 0 … 5000 Hz | |
| Hysteresis | 1 … 10 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | ≤ 2.5 V | |
| Operating current | 0 … 200 mA | |
| No-load supply current | ≤ 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2935 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| Protection class | II | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 … 75 °C (-13 … 167 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | stainless steel 1.4404 / AISI 316L | |
| Sensing face | PBT | |
| Housing diameter | 12 mm | |
| Degree of protection | IP67 | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27270104 |
| ECLASS 10.0.1 | 27270104 |
| ECLASS 9.0 | 27270104 |
| ECLASS 8.0 | 27270104 |
| ECLASS 5.1 | 27270104 |
| ETIM 8.0 | EC002544 |
| ETIM 7.0 | EC002544 |
| ETIM 6.0 | EC002544 |
| ETIM 5.0 | EC002544 |
| UNSPSC 12.1 | 39121550 |