Description
Datasheet excerpt: Technical data of MB35-F12-1N
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NAMUR | |
| Rated operating distance | 35 mm | |
| Installation | flush | |
| Assured operating distance | 0 … 35 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) | |
| Switching frequency | 0 … 5000 Hz | |
| Current consumption | ||
| Magnet detected | ≥ 3 mA | |
| Magnet not detected | ≤ 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 3477 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 | |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 | |
| Approvals and certificates | ||
| IECEx approval | ||
| Equipment protection level Gb | IECEx TUN 20.0007 | |
| Equipment protection level Da | IECEx TUN 20.0007 | |
| ATEX approval | ||
| Equipment protection level Gb | TÜV 20 ATEX 241336 | |
| Equipment protection level Da | TÜV 20 ATEX 241336 | |
| Ambient conditions | ||
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | anodized aluminum | |
| Sensing face | black plastic | |
| Degree of protection | IP67 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27270104 |
| ECLASS 10.0.1 | 27270104 |
| ECLASS 9.0 | 27270104 |
| ECLASS 8.0 | 27270104 |
| ECLASS 5.1 | 27270104 |
| ETIM 8.0 | EC002544 |
| ETIM 7.0 | EC002544 |
| ETIM 6.0 | EC002544 |
| ETIM 5.0 | EC002544 |
| UNSPSC 12.1 | 39121550 |