Datasheet excerpt: Technical data of IPH-F61-V1
| Product Description | ||
|---|---|---|
| LF read/write head for IDENTControl | ||
| General specifications | ||
|---|---|---|
| Operating frequency | 125 kHz | |
| Transfer rate | 2 kBit/s | |
| Sensing range | ||
| Read distance | 2 … 45 mm | |
| Write distance | 2 … 35 mm | |
| Width | max. 65 mm | |
| UL File Number | E87056 | |
| Functional safety related parameters | ||
| MTTFd | 700 a | |
| Mission Time (TM) | 10 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Power consumption | ≤ 1.2 W | |
| Supply | from the IDENTControl | |
| Directive conformity | ||
| Radio equipment | ||
| Directive 2014/53/EU | EN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364 | |
| RoHS | ||
| Directive 2011/65/EU (RoHS) | EN 50581 | |
| Standard conformity | ||
| Degree of protection | EN 60529 | |
| RFID | ISO/IEC 18000-2 | |
| Ambient conditions | ||
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | connector M12 x 1 | |
| Material | ||
| Housing | ABS | |
| Encapsulation compound | WEVO 403FL/300 | |
| Installation | ||
| Distance between two heads | Multiplex on: ≥ 50 mm Multiplex off: ≥ 290 mm | |
| Mass | approx. 50 g | |
| Cable length | 20 cm | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27280401 |
| ECLASS 10.0.1 | 27280401 |
| ECLASS 9.0 | 27280401 |
| ECLASS 8.0 | 27280401 |
| ECLASS 5.1 | 27280401 |
| ETIM 8.0 | EC002998 |
| ETIM 7.0 | EC002998 |
| ETIM 6.0 | EC002998 |
| UNSPSC 12.1 | 43211710 |