TECHNICAL DATA OF ICE1-8IOL-G60L-V1D
Product Description | ||
---|---|---|
Ethernet IO-Link module with 8 inputs/outputs |
General specifications | ||
---|---|---|
UL File Number | E223772 | |
Indicators/operating means | ||
LED indication | see manual | |
Rotary switch | Setting the fieldbus protocol | |
Electrical specifications | ||
Rated operating voltage | 18 … 30 V | |
Nominal voltage | 24 V DC | |
Current consumption | typ. 200 mA | |
Current loading capacity | Max. 2 x 16 A per module (Loop-through current via L-coded power supply) Total current: max. 9 A per module | |
Galvanic isolation | between US and UL | |
Interface 1 | ||
Interface type | Industrial Ethernet | |
Physical | M12, D-coded | |
Protocol | PROFINET IO with media redundancy protocol (MRP) EtherNet/IP with Device Level Ring (DLR) | |
Transfer rate | 10/100 Mbps | |
Inputs/Outputs | ||
Number/Type | 4 x IO-Link Class A (X1 – X4) 4 x IO-Link Class B (X5 – X8) Configurable as: max. 8 IO-Link and 4 digital inputs and outputs max. 12 digital inputs and 4 digital outputs max. 12 digital outputs and 4 digital inputs short-circuit protected | |
Sensor supply | max. 500 mA Per port (X1 – X8) Via L+ (pin 1) | |
Output rated operating current | max. 500 mA Per port (X1 – X8) Via C/Q (pin 4) In addition, a maximum of 2 A per port (X5 – X8) Via UAux (pin 2) | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011 | |
Standard conformity | ||
Degree of protection | EN 60529:2000 | |
Fieldbus standard | Type 1 according to IEC 61131-2 | |
Emitted interference | EN 61000-6-4:2007+A1:2011 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | EN 61131-2:2004 | |
Ambient conditions | ||
Ambient temperature | -20 … 70 °C (-4 … 158 °F) | |
Storage temperature | -40 … 70 °C (-40 … 158 °F) | |
Cold start temperature | -40 °C (-40 °F) | |
Relative humidity | max. 95 % | |
Altitude | 0 … 2000 m | |
Shock and impact resistance | 50 g, 11 ms, all axes | |
Vibration resistance | 15 g at 5 – 500 Hz | |
Pollution degree | 3 | |
Mechanical specifications | ||
Contact elements | PA | |
Degree of protection | IP65/IP67/IP69K | |
Connection | Power Supply M12, L-coded Fieldbus M12, D-coded Inputs/Outputs M12, A-coded | |
Material | ||
Contacts | CuSn, gold-plated CuNi, gold-plated | |
Housing | Diecast zinc | |
Seal | FKM | |
Mass | 500 g | |
Tightening torque, fastening screws | 1 Nm | |
Tightening torque, cable gland | max. 0.5 Nm | |
Construction type | Field housing | |
Tightening torque of clamping screws | 0.5 Nm |
Classifications
System | Classcode |
---|---|
ECLASS 11.0 | 27242608 |
ECLASS 10.0.1 | 27242608 |
ECLASS 9.0 | 27242608 |
ECLASS 8.0 | 27242608 |
ECLASS 5.1 | 27242608 |
ETIM 8.0 | EC001597 |
ETIM 7.0 | EC001597 |
ETIM 6.0 | EC001597 |
ETIM 5.0 | EC001597 |
UNSPSC 12.1 | 32151705 |