Description
TECHNICAL DATA OF HiC2065
| General specifications | ||
|---|---|---|
| Signal type | Analog input | |
| Supply | ||
| Connection | SL1: 1a, 1b(-); 2a, 2b(+) | |
| Rated voltage | 20 … 30 V DC bus powered via Termination Board | |
| Ripple | within the supply tolerance | |
| Rated current | ≤ 22 mA | |
| Power dissipation/power consumption | 0.7 W max. | |
| Lockout voltage | > 11 V DC | |
| Input | ||
| Connection side | field side | |
| Connection | SL2: 5a(+), 5b(-) | |
| Input resistance | ≥ 16 MΩ | |
| Transmission range | 0 … ± 50 mV | |
| Offset voltage/current | ≤ 5 µV / ≤ 5 nA | |
| Output | ||
| Connection side | control side | |
| Connection | SL1: 8a(+), 7a(-) | |
| Voltage | 0 … ± 50 mV | |
| Load | Accuracy figures for infinite load impedance. Additional 0.03 % of span for a load resistance of 10 kΩ | |
| Output resistance | max. 3 Ω | |
| Line fault detection | input: ± 100 mV output: +200 mV, -115 mV | |
| Fault indication output | ||
| Connection | SL1: 6b | |
| Output type | open collector transistor (internal fault bus) | |
| Fault voltage | < Vcc/2 (when connected to Vcc via 10 kΩ pull up resistor) | |
| Transfer characteristics | ||
| Deviation | ||
| After calibration | at 20 °C (68 °F): ± 3 µV up to ± 10mV/± 0.05 % of the span up to +50 mV/± 0.05 % of the span up to -50 mV | |
| Influence of ambient temperature | ± 1 µV/K (typical ± 0.25 µV/K) | |
| Absolute | < 0.25 K at 30 V voltage supply | |
| Bandwidth | DC to > 350 Hz (-3 dB) | |
| Settling time | < 2 ms | |
| Rise time/fall time | ≤ 1 ms | |
| Galvanic isolation | ||
| Output/power supply | functional insulation, rated insulation voltage 50 V AC | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 For further information see system description. | |
| Degree of protection | IEC 60529:2001 | |
| Protection against electrical shock | UL 61010-1 | |
| Ambient conditions | ||
| Ambient temperature | -20 … 60 °C (-4 … 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Mass | approx. 100 g | |
| Dimensions | 12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 inch) | |
| Mounting | on Termination Board | |
| Coding | pin 2, 3 and 4 trimmed For further information see system description. | |
| Data for application in connection with hazardous areas | ||
| EU-type examination certificate | BASEEFA 10 ATEX 0031X | |
| Marking | II (1)GD, I (M1), [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C ≤ Tamb ≤ 60 °C) [circuit(s) in zone 0/1/2] | |
| Voltage | 5.5 V DC | |
| Current | 2.4 mA | |
| Power | 3.3 mW | |
| Supply | ||
| Maximum safe voltage | 253 V (Attention! The rated voltage can be lower.) | |
| Certificate | BASEEFA 10 ATEX 0032X | |
| Marking | II 3G Ex nA II T4 | |
| Galvanic isolation | ||
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Input/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
| International approvals | ||
| UL approval | ||
| Control drawing | 116-0317 (cULus) | |
| IECEx approval | IECEx BAS 10.0012X IECEx BAS 10.0013X | |
| Approved for | [Zone 0] [Ex ia] IIC, [Ex iaD], [Ex ia] I Ex nA II T4 | |
| General information | ||
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 11.0 | 27210120 |
| ECLASS 10.0.1 | 27210120 |
| ECLASS 9.0 | 27210120 |
| ECLASS 8.0 | 27210120 |
| ECLASS 5.1 | 27210120 |
| ETIM 8.0 | EC002653 |
| ETIM 7.0 | EC002653 |
| ETIM 6.0 | EC002653 |
| ETIM 5.0 | EC001485 |
| UNSPSC 12.1 | 32101514 |




II (1)GD, I (M1), [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C ≤ Tamb ≤ 60 °C) [circuit(s) in zone 0/1/2]