Description
TECHNICAL DATA OF 1250L
OPERATOR INTERFACE | 1250 L | |
DISPLAY | Type | LCD black background |
Screen area (L x H) | 37×68 mm (1.46” x 2.68”) | |
Lighting | Backlit with LEDs, life > 40.000 hours @ 25 °C * with brightness level BACKL=0.8 | |
PV Display | Number of digits: 4 to 7 segments, with decimal point Digit height: 17 mm Color: white or “custom” | |
SV Display | Number of digits: 4 to 7 segments, with decimal point Digit height: 14 mm Color: green or “custom” | |
F Display | Number of digits: 5 to 14 segments, with decimal point Digit height: 9 mm Color: ambra or “custom” | |
Engineering units | Selectable, °C, °F or custom 1 Color: same as PV display | |
Alarms state signals | Number: 4 (1, 2, 3, 4) Color: red | |
Bargraph indicator, configurable | Type: graphic bargraph,11 segments Deviation between AL1 and PV | |
KEYPAD | Keys number: 4, silicone ( R, INC,DEC,F) Type: mechanical | |
INPUTS | ||
MAIN INPUT | Sensor type | TC, RTD (PT100, JPT100), infrared sensor, DC linear sensor |
Accuracy | TC inputs: Calibration accuracy: < +/- (0.25% of reading value in °C +0.1°C) Linearization accuracy: 0.1% of reading value Cold junction accuracy: < +/- 1.5°C a 25°C room temperature) Cold junction compensation: > 30:1 rejection to the change of the room RTD input: Calibration accuracy: < +/- (0.15% of reading value in °C +0.4°C) Temperature drift: < +/- (0.005% of reading value in °C +0.015°C )/°C from 25°C room temperature Linearization accuracy: 0.1% of reading value Linear inputs: Calibration accuracy:< 0.1% full scale Temperature drift: < +/- 0.005% full scale /°C at 25°C room temperature | |
Sampling time | 60 ms / 120 ms, selectable | |
Digital filter | 0.0. 20.0 s | |
Temperature unit of measurement | Degrees C / F, selectable from keypad | |
Signal interval | Type: linear Scale: -1999…9999, settable decimal point | |
TC (thermocouple) input | Thermocouple: J, K, R, S, T, C, D, B, E, L, L GOST, U, G, N, Pt20Rh- Pt40Rh Linearization: ITS90 or custom | |
RTD (resistance thermometer) input | Resistance thermometer: PT100, JPT100 Input impedance (Ri): ≥ 30 kΩ Linearization: DIN 43760 or custom Max. line resistance: 20 Ω | |
DC linear input | 0…60 mV input impedance (Ri): > 70 kΩ 0…1 V input impedance (Ri): > 15 kΩ 0…5 V / 0…10 V input impedance (Ri): > 30 kΩ 0/4…20 mA input impedance (Ri): 50 Ω Linearization: linear or custom | |
DIGITAL INPUTS | Type | voltage dry contact, or NPN 24 V – 4.5 mA, or PNP 12/24 V – max 3.6 mA (for detail see electrical connections) |
Isolation | 500 V | |
Number | 5 max |
OUTPUTS | ||
Relay (R)
Analog retransmission (A1) | Number: 4 max Type of relay contact: NO Max. current: 5 A, 250 VAC / 30 VDC, cosj = 1 | |
Minimum load: 5 V, 10 mA Life cycle: > 100,000 operations Double isolation | ||
Number: 1 max 0…10 V, max 20 mA, Rout: > 500 Ω 0…20 mA, 4…20 mA, Rout: < 500 Ω Resolution: 12 bit Isolated from main input | ||
ALARMS | Number of alarm functions | 4 max, assignable to an output |
Possible configurations | Maximum, minimum, symmetric, absolute/relative, exclusion at firing, memory, reset from keypad and/or contact, | |
CONTROL FUNCTIONS | ||
DIAGNOSTIC | Short circuit or open circuit | |
RETENTIVE MEMORY | Type | EEPROM |
Max. number of writes | 1,000.000 | |
SERIAL INTERFACE | ||
Type: RS485 Baudrate: 1200, 2400, 4800, 9600, 19.200, 38.400, 57.600,115.200 bit/s Protocoll: MODBUS RTU Isolated from main input | ||
GENERAL DATA | ||
POWER SUPPLY | Operating voltage | 100…240 VAC/VDC ±10%, 50/60 Hz (on request 20…27 VAC/VDC ±10%) |
Power dissipation | 10 W max | |
Protections | Overvoltage 300 V / 35 V | |
Connection | Screw terminals and crimp connector, max. wire section 1 mm2 | |
CONNECTIONS | Serial configuration port (for USB connection) | Connector: microUSB |
Inputs and outputs | Screw terminals and crimp connector, max. wire section 2,5 mm2 | |
AMBIENT CONDITIONS | Use | Indoor |
Altitude | 2000 m max | |
Operating temperature | -10 … +55 °C (as per IEC 68-2-14) | |
Storage temperature | -20 … +70 °C (as per IEC 68-2-14) | |
Relative humidity | 20…85% RH non-condensing (as per IEC 68-2-3) | |
PROTECTION LEVEL | IP 65 on front panel (as per IEC 68-2-3) | |
ASSEMBLY | Positioning | On panel, removable faceplate |
Installation regulations | Installation category: II; Pollution degree: 2 Isolation: double | |
DIMENSIONS | 48 × 96 mm (1/8 DIN) (1.89” x 3.78”) Depth: 80 mm (3.15”) | |
WEIGHT | 0.24 kg (53 lb) | |
CE STANDARDS | EMC (electromagnetic compatibility) | Conforms to directive 2014/30/EU with reference to standard EN 61326-1 emission in industrial environment class A for models 650 LV, 1250 emission in residential environment class B for models 650 HV |
Safety LVD | conforms to directive 2014/35/EU with reference to standard EN61010-1 |
Code | Description |
F060800 | Cable for programming with PC, USB-TTL 3 V with USB – microUSB connectors, length 1.8 m |
F043958 | “GF_eXpress” software CD |
F060909 | Configuration kit for new instruments GF_eXK-3-0-0 |
51969 | Rubber gasket 48×96 for display |
51068 | Rubber gasket 48×96 for panel |
49030 | Fastening clip (models 1250 L) |
51328 | Finger safe cover (models 1250 L) |
51738 | 36 replacement terminals (model 1250 L) |