Description
Datasheet excerpt: Technical data of UC800-F77S-IU-IO-V31
Product Description | ||
---|---|---|
Single head system |
General specifications | ||
---|---|---|
Sensing range | 60 … 800 mm | |
Adjustment range | 70 … 800 mm | |
Dead band | 0 … 60 mm | |
Standard target plate | 100 mm x 100 mm | |
Transducer frequency | approx. 255 kHz | |
Response delay | minimum : 13 ms factory setting: 49 ms | |
Sensor cycle time | ≥ 13 ms (factory setting) ; programmable to 60 s | |
Memory | ||
Non-volatile memory | EEPROM | |
Write cycles | 300000 | |
Indicators/operating means | ||
LED green | solid: power on flashing: standby mode or IO-Link communication | |
LED yellow | solid: object in evaluation range flashing: programming of the limits, object detected | |
LED red | solid: fault flashing: programming limits, object not detected | |
Electrical specifications | ||
Operating voltage | 18 … 30 V DC , ripple 10 %SS | |
No-load supply current | ≤ 50 mA | |
Power consumption | ≤ 500 mW | |
Time delay before availability | ≤ 300 ms | |
Interface | ||
Interface type | IO-Link (available after activation via programming button until next reset) | |
Input/Output | ||
Input/output type | 1 synchronization connection, bidirectional | |
0 Level | 0 … 1 V | |
1 Level | 2.5 V … UB | |
Input impedance | > 22 kΩ | |
Output rated operating current | current source < 2.5 mA | |
Pulse length | ≥ 1 ms with external control, low active | |
Synchronization frequency | ||
Common mode operation | ≤ 82 Hz | |
Multiplex operation | ≤ 82 Hz / n , n = number of sensors , n ≤ 10 | |
Output | ||
Output type | 1 analog output 0 (4) … 20 mA or 1 analog output 0 … 10 V | |
Resolution | current output: evaluation range [mm]/3200 but ≥ 0.35 mm voltage output: evaluation range [mm]/4000 but ≥ 0.35 mm | |
Deviation of the characteristic curve | ≤ ± 1 % of full-scale value | |
Repeat accuracy | ≤ ± 0.1 % of full-scale value | |
Load impedance | current output: ≤ 500 Ohm voltage output: ≥ 1000 Ohm | |
Temperature influence | ≤ ± 0.75 % of the end value (with temperature compensation) from 10 minutes after switching on the sensor ; 0.17 %/K (without temperature compensation) | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
Approvals and certificates | ||
UL approval | cULus Listed, Class 2 Power Source | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | current output -25 … 60 °C (-13 … 140 °F) voltage output -25 … 70 °C (-13 … 158 °F) When fixing with one M18 nut, the temperature range for each begins with 0 °C (32 °F). | |
Storage temperature | -40 … 85 °C (-40 … 185 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M8 x 1 , 4-pin | |
Degree of protection | IP67 | |
Material | ||
Housing | Polycarbonate | |
Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam | |
Installation position | any position | |
Mass | 13 g | |
Tightening torque, fastening screws | with M3 nuts max. 0.2 Nm with M18 nuts max. 1 Nm | |
Factory settings | ||
Output | near limit: 70 mm far limit: 800 mm Output mode: rising ramp output type: 4 … 20 mA | |
Beam width | wide |
Classifications
System | Classcode |
---|---|
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
Reviews
There are no reviews yet.