Description
TECHNICAL DATA OF CM
Accuracy | 0,2% | |
Nominal full scale load (Ln) | 100. 50.000 Kg | |
Nominal output at FSO | 2mV/V | |
Output tolerance at Ln | <± 0,2% FSO | |
Combined errors: Non linearity Histeresis, Repeatibility | < ± 0,2% FSO | |
Creep (after 30 min. at Ln) | < ± 0,06% FSO | |
Zero load out of balance signal | < ± 1% FSO | |
Calibration signal * | 80%FSO ± 1% | |
Thermal drift in Sensitivity | < ± 0,01% FSO°C | |
compensated | Zero | < ± 0,01% FSO°C |
range Calibration | < ± 0,01% FSO°C | |
Nominal input resistance | 700 Ohm | |
Nominal output resistance | 700 Ohm | |
Isolation resistance | > 10 GOhm | |
Nominal supply voltage | 10 V | |
Maximum supply voltage | 15 V | |
Compensated temperature range | -10…+50°C | |
Maximum temperature range | -20…+60°C | |
Storage temperature range | -30…+80°C | |
Permitted static load | 130% Ln | |
Permitted dinamic load | 100% Ln | |
Maximum applicable load | 150% Ln | |
Rupture load | > 300% Ln | |
Maximum elastic deformation at Ln | < 0,2 mm | |
Grade of protection (DIN40050) | Cable: IP67 Connector: IP65 | |
Electr. connections: Connector Screened cable | VPT02A10-6PT2 6×0,25 / 5 m. | |
Elastic element material | Stainless steel | |
* The exact value is indicated on the instrument nameplate |