{"id":808,"date":"2021-09-11T03:05:47","date_gmt":"2021-09-11T03:05:47","guid":{"rendered":"https:\/\/newskyvn.com\/?post_type=product&#038;p=808"},"modified":"2021-09-11T03:06:37","modified_gmt":"2021-09-11T03:06:37","slug":"lgm50","status":"publish","type":"product","link":"https:\/\/newskyvn.com\/en\/product\/lgm50\/","title":{"rendered":"LGM50"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p id=\"techdata\"><strong><span style=\"color: #0000ff;\">Datasheet excerpt: Technical data of\u00a0 LGM50<\/span><\/strong><\/p>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th colspan=\"2\">Product Description<\/th>\n<\/tr>\n<tr>\n<td colspan=\"3\">Measuring automation light grid with beam spacing of 50 mm, IO-Link interface, push-pull output, fixed cable with M12 plug<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th colspan=\"3\">General specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Effective detection range<\/td>\n<td>Standard : 0.3 &#8230; 6 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Threshold detection range<\/td>\n<td>7.5 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Light source<\/td>\n<td>IRED<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Light type<\/td>\n<td>modulated infrared light , 850 nm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Field height<\/td>\n<td>see Table 1, max. 3000 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Beam crossover<\/td>\n<td>Factory setting: three beam crossing, deactivateable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Beam blanking<\/td>\n<td>adjustable max. 2 fixed suppressible beam areas (blanking)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Beam spacing<\/td>\n<td>50 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Number of beams<\/td>\n<td>see Table 1, max. 61<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating mode<\/td>\n<td>Emitter: Emitter power adjustable in two ranges<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Optical resolution<\/td>\n<td>without beam crossover: 50 mm<br \/>\nwith beam crossover: 25 mm with in 25%\u00a0 and \u00a075% of the range<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Angle of divergence<\/td>\n<td>10 \u00b0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient light limit<\/td>\n<td>&gt; 50000 Lux (if external light source is outside the opening angle)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Functional safety related parameters<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">MTTF<sub>d<\/sub><\/td>\n<td>56 a<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mission Time (T<sub>M<\/sub>)<\/td>\n<td>20 a<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Diagnostic Coverage (DC)<\/td>\n<td>60 %<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Indicators\/operating means<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operation indicator<\/td>\n<td>LED green:<br \/>\nconstantly on &#8211; power-on<br \/>\ndouble pulse flashing (0.8 Hz) &#8211; undervoltage<br \/>\nflashing (4 Hz) &#8211; short circuit<br \/>\nflashing with short interruptions (1 Hz) &#8211; IO-Link mode<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Status indicator<\/td>\n<td>Emitter: LED yellow<br \/>\nconstantly on &#8211; high emitter power<br \/>\nconstantly off &#8211; low emitter power<br \/>\nflashing (8 Hz) &#8211; error message<br \/>\nReceiver: LED yellow:<br \/>\nconstantly on &#8211; object detected<br \/>\nconstantly off &#8211; no object detected<br \/>\nflashing (4 Hz) &#8211; below stability control limit<br \/>\nflashing (8 Hz) &#8211; error message<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Control elements<\/td>\n<td>Receiver: 2 touch buttons for programming<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Electrical specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating voltage<\/td>\n<td>18 &#8230; 30 V DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ripple<\/td>\n<td>10 %<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">No-load supply current<\/td>\n<td>Emitter \u2264: 50 mA<br \/>\nReceiver: \u2264 150 mA (without outputs)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Time delay before availability<\/td>\n<td>see Table 1, max. 1.5 s<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Interface<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Interface type<\/td>\n<td>IO-Link ( pin 4 )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">IO-Link revision<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Device ID<\/td>\n<td>1050371 &#8230; 1050398 ( 0x100703 &#8230; 0x10071E )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">COM-Mode<\/td>\n<td>COM\u00a02 (38.4 kBaud)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Min. cycle time<\/td>\n<td>2.3 ms<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Process data width<\/td>\n<td>16 bit<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">SIO mode support<\/td>\n<td>yes<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Input<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Test input<\/td>\n<td>Emitter switch-off with +UB or 0\u00a0V at pin 4 (emitter)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Function input<\/td>\n<td>Range input activation from 1.6 m with +UB or 0 V on pin 2 (emitter)<br \/>\nTeach-In input for parameterization on pin 8 (receiver)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Pre-fault indication output<\/td>\n<td>Stability Control (SC) 1 PNP, short-circuit protected, reverse polarity protected on pin 2 (receiver)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching type<\/td>\n<td>Factory setting: dark on , Switchable to light-on mode<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Signal output<\/td>\n<td>Command interface: Pin 4 IO-Link interface C or used as switching output Q; 1 short-circuit proof reverse polarity protected push-pull output (receiver)<br \/>\nSwitch output: Pin 5 switching output Q; 1 short-circuit proof reverse polarity protected push-pull output (receiver) synchronized with pin 4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching threshold<\/td>\n<td>Factory setting: The signal tracking for the threshold value is deactivated, increasing the optical resolution by a maximum of 4\u00a0mm; switchable to active signal tracking<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching voltage<\/td>\n<td>max. 30 V DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching current<\/td>\n<td>max. 100 mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Voltage drop<\/td>\n<td>\u2264 2 V DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching frequency<\/td>\n<td>see Table 1, max. 129 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Response time<\/td>\n<td>see Table 1, max. 8 ms<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Timer function<\/td>\n<td>Off-delay programmable from 0 &#8230; 1.25 s in 5 ms steps (adjustment via IO-Link only)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Conformity<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Communication interface<\/td>\n<td>IEC 61131-9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Product standard<\/td>\n<td>EN 60947-5-2<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Approvals and certificates<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Protection class<\/td>\n<td>III ( IEC\u00a061140 )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">UL approval<\/td>\n<td>cULus Listed<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">CCC approval<\/td>\n<td>CCC approval \/ marking not required for products rated \u226436 V<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Ambient conditions<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient temperature<\/td>\n<td>-30 &#8230; 60 \u00b0C (-22 &#8230; 140 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Storage temperature<\/td>\n<td>-30 &#8230; 70 \u00b0C (-22 &#8230; 158 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Mechanical specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Conductor cross section<\/td>\n<td>min. 0.25 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Housing width<\/td>\n<td>20 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Housing depth<\/td>\n<td>30.5 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Housing length L<\/td>\n<td>see Table 1, max. 3160 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Degree of protection<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>Emitter: connecting cable with 4-pin, M12 x 1 connector , 330 mm total length<br \/>\nReceiver: connecting cable with 8-pin, M12 x 1 connector , 350 mm total length<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Material<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Housing<\/td>\n<td class=\"subattribute\">extruded aluminum section , Silver anodized<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Optical face<\/td>\n<td class=\"subattribute\">Plastic pane , Polycarbonate<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mass<\/td>\n<td>see Table 1, max. 1650 g (per profile)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Cable length<\/td>\n<td>max. 30 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #0000ff;\"><strong>Classifications<\/strong><\/span><\/p>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th>System<\/th>\n<th>Classcode<\/th>\n<\/tr>\n<tr>\n<td>ECLASS 11.0<\/td>\n<td>27270910<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 10.0.1<\/td>\n<td>27270910<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 9.0<\/td>\n<td>27270910<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 8.0<\/td>\n<td>27270910<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 5.1<\/td>\n<td>27270910<\/td>\n<\/tr>\n<tr>\n<td>ETIM 8.0<\/td>\n<td>EC002549<\/td>\n<\/tr>\n<tr>\n<td>ETIM 7.0<\/td>\n<td>EC002549<\/td>\n<\/tr>\n<tr>\n<td>ETIM 6.0<\/td>\n<td>EC002549<\/td>\n<\/tr>\n<tr>\n<td>ETIM 5.0<\/td>\n<td>EC002549<\/td>\n<\/tr>\n<tr>\n<td>UNSPSC 12.1<\/td>\n<td>39121528<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<ul id=\"productfeatures\">\n<li>Measuring automation light grid with switching output<\/li>\n<li>Optical resolution 50 mm<\/li>\n<li>Super-fast object detection, even with 3-way beam crossover<\/li>\n<li>Object identification using integrated object recognition<\/li>\n<li>IO-Link interface for service and process data<\/li>\n<li>Temperature range to -30\u00a0\u00b0C<\/li>\n<li>Output of a measured value, can be selected from a number of measuring functions<\/li>\n<\/ul>\n","protected":false},"featured_media":810,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[24,37],"product_tag":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.6.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>LGM50 - NEW SKY CO.,LTD<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/newskyvn.com\/product\/lgm50\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"LGM50 - NEW SKY CO.,LTD\" \/>\n<meta property=\"og:description\" content=\"[:vi]  \u0110o l\u01b0\u1edbi tia s\u00e1ng t\u1ef1 \u0111\u1ed9ng h\u00f3a v\u1edbi \u0111\u1ea7u ra chuy\u1ec3n m\u1ea1ch  \u0110\u1ed9 ph\u00e2n gi\u1ea3i quang h\u1ecdc 50 mm  Ph\u00e1t hi\u1ec7n \u0111\u1ed1i t\u01b0\u1ee3ng si\u00eau nhanh, ngay c\u1ea3 v\u1edbi ch\u00f9m tia 3 chi\u1ec1u giao nhau  Nh\u1eadn d\u1ea1ng \u0111\u1ed1i t\u01b0\u1ee3ng b\u1eb1ng nh\u1eadn d\u1ea1ng \u0111\u1ed1i t\u01b0\u1ee3ng t\u00edch h\u1ee3p  Giao di\u1ec7n IO-Link cho d\u1eef li\u1ec7u d\u1ecbch v\u1ee5 v\u00e0 quy tr\u00ecnh  Ph\u1ea1m vi nhi\u1ec7t \u0111\u1ed9 \u0111\u1ebfn -30 \u00b0 C  \u0110\u1ea7u ra c\u1ee7a gi\u00e1 tr\u1ecb \u0111o, c\u00f3 th\u1ec3 \u0111\u01b0\u1ee3c ch\u1ecdn t\u1eeb m\u1ed9t s\u1ed1 ch\u1ee9c n\u0103ng \u0111o [:en]  Measuring automation light grid with switching output  Optical resolution 50 mm  Super-fast object detection, even with 3-way beam crossover  Object identification using integrated object recognition  IO-Link interface for service and process data  Temperature range to -30\u00a0\u00b0C  Output of a measured value, can be selected from a number of measuring functions [:]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/newskyvn.com\/product\/lgm50\/\" \/>\n<meta property=\"og:site_name\" content=\"NEW SKY CO.,LTD\" \/>\n<meta property=\"article:modified_time\" content=\"2021-09-11T03:06:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/LGM50.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/newskyvn.com\/#website\",\"url\":\"https:\/\/newskyvn.com\/\",\"name\":\"NEW SKY CO.,LTD\",\"description\":\"C\\u00f4ng Ty TNHH S\\u1ea3n Xu\\u1ea5t Th\\u01b0\\u01a1ng M\\u1ea1i D\\u1ecbch V\\u1ee5 T\\u00e2n Thi\\u00ean\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/newskyvn.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/newskyvn.com\/product\/lgm50\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/LGM50.jpg\",\"contentUrl\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/LGM50.jpg\",\"width\":500,\"height\":500},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/newskyvn.com\/product\/lgm50\/#webpage\",\"url\":\"https:\/\/newskyvn.com\/product\/lgm50\/\",\"name\":\"LGM50 - NEW SKY CO.,LTD\",\"isPartOf\":{\"@id\":\"https:\/\/newskyvn.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/newskyvn.com\/product\/lgm50\/#primaryimage\"},\"datePublished\":\"2021-09-11T03:05:47+00:00\",\"dateModified\":\"2021-09-11T03:06:37+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/newskyvn.com\/product\/lgm50\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/newskyvn.com\/product\/lgm50\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/newskyvn.com\/product\/lgm50\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Product\",\"item\":\"https:\/\/newskyvn.com\/en\/san-pham\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"LGM50\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product\/808"}],"collection":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/comments?post=808"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media\/810"}],"wp:attachment":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media?parent=808"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_cat?post=808"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_tag?post=808"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}