{"id":631,"date":"2021-09-08T13:25:56","date_gmt":"2021-09-08T13:25:56","guid":{"rendered":"http:\/\/thanh.halink.asia\/newskyvn\/?post_type=product&#038;p=631"},"modified":"2024-09-15T12:48:33","modified_gmt":"2024-09-15T12:48:33","slug":"mlv11-54-ex-40b-112","status":"publish","type":"product","link":"https:\/\/newskyvn.com\/en\/product\/mlv11-54-ex-40b-112\/","title":{"rendered":"MLV11-54-Ex\/40b\/112"},"content":{"rendered":"<p><\/p>\n<p id=\"techdata\"><strong><span style=\"color: #0000ff;\">Datasheet excerpt: Technical data of\u00a0 MLV11-54-Ex\/40b\/112<\/span><\/strong><\/p>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th colspan=\"2\">Product Description<\/th>\n<\/tr>\n<tr>\n<td colspan=\"3\">NAMUR retroreflective sensor, small housing design, 3 m detection range, red light, light\/dark on, DC version, NAMUR output, M12 plug<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th colspan=\"3\">General specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Effective detection range<\/td>\n<td>0 &#8230; 3 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Reflector distance<\/td>\n<td>300 &#8230; 3000 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Threshold detection range<\/td>\n<td>3 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Reference target<\/td>\n<td>H85 reflector<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Light source<\/td>\n<td>LED<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Light type<\/td>\n<td>modulated visible red light , 660 nm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Polarization filter<\/td>\n<td>yes<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient light limit<\/td>\n<td>\u2264 10000 Lux sun light<br \/>\n\u2264 7500 Lux halogen light<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Functional safety related parameters<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">MTTF<sub>d<\/sub><\/td>\n<td>1319 a<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mission Time (T<sub>M<\/sub>)<\/td>\n<td>20 a<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Diagnostic Coverage (DC)<\/td>\n<td>0 %<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Indicators\/operating means<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Function indicator<\/td>\n<td>LED yellow: switching state<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Control elements<\/td>\n<td>sensitivity adjustment<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Electrical specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating voltage<\/td>\n<td>6 &#8230; 15.5 V DC (R<sub>i<\/sub>\u00a0approx. 0 Ohm)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ripple<\/td>\n<td>5 %<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power consumption<\/td>\n<td>max. 64 mW<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Time delay before availability<\/td>\n<td>20 ms<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching type<\/td>\n<td>light\/dark on, programmable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Signal output<\/td>\n<td>1 NAMUR output NC\/NO programmable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching voltage<\/td>\n<td>8 V DC (R<sub>i<\/sub>\u00a0approx. 1 k\u03a9)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching frequency<\/td>\n<td>\u2264 100 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Current consumption<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Reference target detected<\/td>\n<td class=\"subattribute\">connection 1, 2: \u2265 2.2 mA<br \/>\nconnection 1, 4: \u2264 1 mA<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Reference target not detected<\/td>\n<td class=\"subattribute\">connection 1, 2: \u2264 1 mA<br \/>\nconnection 1, 4: \u2265 2.2 mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Response time<\/td>\n<td>5 ms<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Conformity<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Product standard<\/td>\n<td>EN 60947-5-2<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Approvals and certificates<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">CCC approval<\/td>\n<td>CCC approval \/ marking not required for products rated \u226436 V<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Ambient conditions<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient temperature<\/td>\n<td>-25 &#8230; 70 \u00b0C (-13 &#8230; 158 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Storage temperature<\/td>\n<td>-40 &#8230; 80 \u00b0C (-40 &#8230; 176 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Mechanical specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Housing width<\/td>\n<td>18 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Housing height<\/td>\n<td>50 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Housing depth<\/td>\n<td>45 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Degree of protection<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>V1 connector (M12\u00a0x\u00a01), 4-pin, rotatable through 90\u00b0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Material<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Housing<\/td>\n<td class=\"subattribute\">PBT<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Optical face<\/td>\n<td class=\"subattribute\">scratch resistant plastic lens<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mass<\/td>\n<td>60 g<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">ATEX G<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">EC-Type Examination Certificate<\/td>\n<td>PTB 99 ATEX 2036X<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Applicant<\/td>\n<td>Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">CE marking<\/td>\n<td>CE0102<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">ATEX marking<\/td>\n<td>Zone 1:\u00a0<img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II 2G Ex ia op is IIC T6&#8230;T1 Gb<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Directive conformity<\/td>\n<td>2014\/34\/EU<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Standards<\/td>\n<td>EN 60079-0:2012+A11:2013<br \/>\nEN 60079-11:2012<br \/>\nEN 60079-28:2007<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Effective internal capacitance C<sub>i<\/sub><\/td>\n<td>max. 120 nF<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Effective internal inductance L<sub>i<\/sub><\/td>\n<td>negligibly small<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">General<\/td>\n<td>The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient temperature<\/td>\n<td>The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Installation, commissioning<\/td>\n<td>The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and\/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Maintenance<\/td>\n<td>No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><b>Special conditions<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Protection from mechanical danger<\/td>\n<td class=\"subattribute\">When used in the temperature range below -20 \u00b0C the sensor should be protected from knocks by the provision of an additional housing.<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Degree of protection required when installing connecting components<\/td>\n<td class=\"subattribute\">IP20 according to IEC 60529:2001<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Other conditions<\/td>\n<td class=\"subattribute\">Refer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">IECEx G<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Certificate number<\/td>\n<td>IECEx PTB 12.0061 X<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Applicant<\/td>\n<td>Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">IECEx marking<\/td>\n<td>Zone 1:\u00a0<img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II 2G Ex ia op is IIC T6&#8230;T1 Gb<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Standards<\/td>\n<td>IEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Effective internal capacitance C<sub>i<\/sub><\/td>\n<td>max. 120 nF<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Effective internal inductance L<sub>i<\/sub><\/td>\n<td>negligibly small<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">General<\/td>\n<td>The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient temperature<\/td>\n<td>The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Installation, commissioning<\/td>\n<td>The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and\/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Maintenance<\/td>\n<td>No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><b>Special conditions<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Protection from mechanical danger<\/td>\n<td class=\"subattribute\">When used in the temperature range below -20 \u00b0C the sensor should be protected from knocks by the provision of an additional housing.<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Degree of protection required when installing connecting components<\/td>\n<td class=\"subattribute\">IP20 according to IEC 60529:2001<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Other conditions<\/td>\n<td class=\"subattribute\">Refer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><span style=\"color: #0000ff;\">Classifications<\/span><\/strong><\/p>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th>System<\/th>\n<th>Classcode<\/th>\n<\/tr>\n<tr>\n<td>ECLASS 11.0<\/td>\n<td>27270902<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 10.0.1<\/td>\n<td>27270902<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 9.0<\/td>\n<td>27270902<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 8.0<\/td>\n<td>27270902<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 5.1<\/td>\n<td>27270902<\/td>\n<\/tr>\n<tr>\n<td>ETIM 8.0<\/td>\n<td>EC002717<\/td>\n<\/tr>\n<tr>\n<td>ETIM 7.0<\/td>\n<td>EC002717<\/td>\n<\/tr>\n<tr>\n<td>ETIM 6.0<\/td>\n<td>EC002717<\/td>\n<\/tr>\n<tr>\n<td>ETIM 5.0<\/td>\n<td>EC002717<\/td>\n<\/tr>\n<tr>\n<td>UNSPSC 12.1<\/td>\n<td>39121528<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<ul id=\"productfeatures\">\n<li>ATEX approval for zone 1 (Gas)<\/li>\n<li>Intrinsically safe, Ex op is ia IIC T6 Gb<\/li>\n<li>Glare protected with polarization filter<\/li>\n<li>Adjustable sensitivity<\/li>\n<\/ul>\n","protected":false},"featured_media":632,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[24,43],"product_tag":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.6.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>MLV11-54-Ex\/40b\/112 - NEW SKY CO.,LTD<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/newskyvn.com\/product\/mlv11-54-ex-40b-112\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MLV11-54-Ex\/40b\/112 - NEW SKY CO.,LTD\" \/>\n<meta property=\"og:description\" content=\"[:vi]  \u0110\u1ea1t chu\u1ea9n ch\u1ed1ng ch\u00e1y ATEX cho khu v\u1ef1c 1 (Kh\u00ed \u0111\u1ed1t)  An to\u00e0n n\u1ed9i t\u1ea1i, Ex op l\u00e0 IIC T6 Gb  Ch\u1ed1ng ch\u00f3i v\u1edbi b\u1ed9 l\u1ecdc ph\u00e2n c\u1ef1c  C\u00f3 th\u1ec3 \u0111i\u1ec1u ch\u1ec9nh \u0111\u1ed9 nh\u1ea1y [:en]  ATEX approval for zone 1 (Gas)  Intrinsically safe, Ex op is ia IIC T6 Gb  Glare protected with polarization filter  Adjustable sensitivity [:]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/newskyvn.com\/product\/mlv11-54-ex-40b-112\/\" \/>\n<meta property=\"og:site_name\" content=\"NEW SKY CO.,LTD\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-15T12:48:33+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/MLV11.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/newskyvn.com\/#website\",\"url\":\"https:\/\/newskyvn.com\/\",\"name\":\"NEW SKY CO.,LTD\",\"description\":\"C\\u00f4ng Ty TNHH S\\u1ea3n Xu\\u1ea5t Th\\u01b0\\u01a1ng M\\u1ea1i D\\u1ecbch V\\u1ee5 T\\u00e2n Thi\\u00ean\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/newskyvn.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/newskyvn.com\/product\/mlv11-54-ex-40b-112\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/MLV11.jpg\",\"contentUrl\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/MLV11.jpg\",\"width\":500,\"height\":500},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/newskyvn.com\/product\/mlv11-54-ex-40b-112\/#webpage\",\"url\":\"https:\/\/newskyvn.com\/product\/mlv11-54-ex-40b-112\/\",\"name\":\"MLV11-54-Ex\/40b\/112 - NEW SKY CO.,LTD\",\"isPartOf\":{\"@id\":\"https:\/\/newskyvn.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/newskyvn.com\/product\/mlv11-54-ex-40b-112\/#primaryimage\"},\"datePublished\":\"2021-09-08T13:25:56+00:00\",\"dateModified\":\"2024-09-15T12:48:33+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/newskyvn.com\/product\/mlv11-54-ex-40b-112\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/newskyvn.com\/product\/mlv11-54-ex-40b-112\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/newskyvn.com\/product\/mlv11-54-ex-40b-112\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Product\",\"item\":\"https:\/\/newskyvn.com\/en\/san-pham\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"MLV11-54-Ex\/40b\/112\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product\/631"}],"collection":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/comments?post=631"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media\/632"}],"wp:attachment":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media?parent=631"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_cat?post=631"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_tag?post=631"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}