{"id":1954,"date":"2021-09-29T09:38:17","date_gmt":"2021-09-29T09:38:17","guid":{"rendered":"https:\/\/newskyvn.com\/?post_type=product&#038;p=1954"},"modified":"2024-11-09T09:37:17","modified_gmt":"2024-11-09T09:37:17","slug":"hic2081","status":"publish","type":"product","link":"https:\/\/newskyvn.com\/en\/product\/hic2081\/","title":{"rendered":"HiC2081"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><span style=\"color: #0000ff;\"><strong>TECHNICAL DATA OF HiC2081<\/strong><\/span><\/p>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th colspan=\"3\">General specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Signal type<\/td>\n<td>Analog input<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Functional safety related parameters<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safety Integrity Level (SIL)<\/td>\n<td>SIL 2<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Supply<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL1: 1a(-), 1b(-); 2a(+), 2b(+)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated voltage<\/td>\n<td>20 &#8230; 30 V DC bus powered via Termination Board<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ripple<\/td>\n<td>within the supply tolerance<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power dissipation\/power consumption<\/td>\n<td>\u2264 0.98 W \/ 0.98 W<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Interface<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Programming interface<\/td>\n<td>programming socket<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Input<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection side<\/td>\n<td>field side<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL2: 5a(+), 1a(+), 1b(-), 5b(-)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">RTD<\/td>\n<td>type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)<br \/>\ntype Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)<br \/>\ntype Cu10, Cu50, Cu100 (P50353-92)<br \/>\ntype Ni100 (DIN 43760)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Measuring current<\/td>\n<td class=\"subattribute\">approx. 200 \u00b5A with RTD<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Types of measuring<\/td>\n<td class=\"subattribute\">2-, 3-, 4-wire connection<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Lead resistance<\/td>\n<td class=\"subattribute\">max. 50 \u03a9 per line<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Measurement loop monitoring<\/td>\n<td class=\"subattribute\">sensor breakage, sensor short-circuit<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Thermocouples<\/td>\n<td>type B, E, J, K, N, R, S, T (IEC\u00a0584-1:\u00a01995)<br \/>\ntype L (DIN\u00a043710:\u00a01985)<br \/>\ntype TXK, TXKH, TXA (P8.585-2001)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Cold junction compensation<\/td>\n<td class=\"subattribute\">external and internal<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Measurement loop monitoring<\/td>\n<td class=\"subattribute\">sensor breakage<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Potentiometer<\/td>\n<td>0 &#8230; 20 k\u03a9 (2-wire connection), 0.8 &#8230; 20 k\u03a9 (3-wire connection)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Types of measuring<\/td>\n<td class=\"subattribute\">3-wire connection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Voltage<\/td>\n<td>selectable within the range -100 &#8230; 100 mV<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Input resistance<\/td>\n<td>\u2265 1 M\u03a9 (-100 &#8230; 100 mV)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection side<\/td>\n<td>control side<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL1: 8a(+), 7a(-)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output<\/td>\n<td>Analog current output<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Current range<\/td>\n<td class=\"subattribute\">0 &#8230; 20 mA or 4 &#8230; 20 mA<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Fault signal<\/td>\n<td class=\"subattribute\">downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Source<\/td>\n<td class=\"subattribute\">load 0 &#8230; 550 \u03a9<br \/>\nopen-circuit voltage \u2264 18 V<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Sink<\/td>\n<td class=\"subattribute\">Voltage across terminals 5 &#8230; 30 V. If the current is supplied from a source &gt; 25 V,<br \/>\nseries resistance of \u2265 (V &#8211; 25)\/0.0215 \u03a9 is needed, where V is the source voltage.<br \/>\nThe maximum value of the resistance is (V &#8211; 5)\/0.0215 \u03a9.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Fault indication output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL1: 6b<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output type<\/td>\n<td>open collector transistor (internal fault bus)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Transfer characteristics<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Deviation<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>After calibration<\/td>\n<td class=\"subattribute\"><u>Pt100:<\/u>\u00a0\u00b1 (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection))<br \/>\n<u>thermocouple:<\/u>\u00a0\u00b1 (0.05 % of measurement value in \u00b0C + 0.1 % of span + 1 K (1.2 K for types R and S))<br \/>\nthis includes \u00b1 0.8 K error of the cold junction compensation<br \/>\n<u>mV:<\/u>\u00a0\u00b1 (50 \u00b5V + 0.1 % of span)<br \/>\n<u>potentiometer:<\/u>\u00a0\u00b1 (0.05 % of full scale + 0.1 % of span, (excludes errors due to lead resistance))<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Influence of ambient temperature<\/td>\n<td class=\"subattribute\">deviation of CJC included:<br \/>\n<u>Pt100:<\/u>\u00a0\u00b1 (0.0015 % of measurement value in K + 0.006 % of span)\/K \u0394T<sub>amb<\/sub><sup>*)<\/sup><br \/>\n<u>thermocouple:<\/u>\u00a0\u00b1 (0.02 K + 0.005 % of measurement value in \u00b0C + 0.006 % of span)\/K \u0394T<sub>amb<\/sub><sup>*)<\/sup><br \/>\n<u>mV:<\/u>\u00a0\u00b1 (0.01 % of measurement value + 0.006 % of span)\/K \u0394T<sub>amb<\/sub><sup>*)<\/sup><br \/>\n<u>potentiometer:<\/u>\u00a0\u00b1 0.006 % of span\/K \u0394T<sub>amb<\/sub><sup>*)<\/sup><br \/>\n<sup>*)<\/sup>\u00a0\u0394T<sub>amb<\/sub>\u00a0= ambient temperature change referenced to 23 \u00b0C (296 K)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Influence of supply voltage<\/td>\n<td class=\"subattribute\">&lt; 0.01 % of span<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Influence of load<\/td>\n<td class=\"subattribute\">\u2264 0.001 % of output value per 100 \u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Reaction time<\/td>\n<td>worst case value (sensor breakage and\/or sensor short circuit detection enabled)<br \/>\nmV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Galvanic isolation<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output\/supply, programming input<\/td>\n<td>functional insulation, rated insulation voltage 50 V AC<br \/>\nThere is no electrical isolation between the programming input and the supply.<br \/>\nThe programming cable provides galvanic isolation so that ground loops are avoided.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Indicators\/settings<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Display elements<\/td>\n<td>LEDs<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Control elements<\/td>\n<td>DIP-switch<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Configuration<\/td>\n<td>via DIP switches<br \/>\nvia PACTware<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Labeling<\/td>\n<td>space for labeling at the front<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Directive conformity<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Electromagnetic compatibility<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Directive 2014\/30\/EU<\/td>\n<td class=\"subattribute\">EN 61326-1:2013 (industrial locations)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Conformity<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Electromagnetic compatibility<\/td>\n<td>NE 21:2012<br \/>\nEN 61326-3-2:2008<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Degree of protection<\/td>\n<td>IEC 60529:2001<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Protection against electrical shock<\/td>\n<td>UL 61010-1:2012<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Ambient conditions<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient temperature<\/td>\n<td>-20 &#8230; 60 \u00b0C (-4 &#8230; 140 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Relative humidity<\/td>\n<td>5 &#8230; 90 %, non-condensing up to 35 \u00b0C (95 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Mechanical specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Degree of protection<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mass<\/td>\n<td>approx. 100 g<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Dimensions<\/td>\n<td>12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 inch)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mounting<\/td>\n<td>on Termination Board<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Coding<\/td>\n<td>pin 1, 2 and 4 trimmed<br \/>\nFor further information see system description.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Data for application in connection with hazardous areas<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">EU-type examination certificate<\/td>\n<td>BASEEFA 14 ATEX 0129 X<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Marking<\/td>\n<td class=\"subattribute\"><img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II (1)G [Ex ia Ga] IIC<br \/>\n<img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II (1)D [Ex ia Da] IIIC<br \/>\n<img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0I (M1) [Ex ia Ma] I<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Input<\/td>\n<td class=\"subattribute\">[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Voltage<\/td>\n<td class=\"subattribute\">9 V<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Current<\/td>\n<td class=\"subattribute\">13.1 mA<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Power<\/td>\n<td class=\"subattribute\">30 mW<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Analog outputs, power supply, collective error<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Maximum safe voltage<\/td>\n<td class=\"subattribute\">250 V (Attention! This is not the rated voltage.)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Interface<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Maximum safe voltage<\/td>\n<td class=\"subattribute\">250 V (Attention! The rated voltage is lower.), RS 232<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Certificate<\/td>\n<td>BASEEFA 14 ATEX 0130 X<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Marking<\/td>\n<td class=\"subattribute\"><img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II 3G Ex nA II T4 Gc [device in zone 2]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Galvanic isolation<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Input\/Other circuits<\/td>\n<td class=\"subattribute\">safe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Directive conformity<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Directive 2014\/34\/EU<\/td>\n<td class=\"subattribute\">EN 60079-0:2012+A11:2013 , EN\u00a060079-11:2012 , EN 60079-15:2010<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">International approvals<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">UL approval<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Control drawing<\/td>\n<td class=\"subattribute\">116-0391 (cULus)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">IECEx approval<\/td>\n<td>IECEx BAS 14.0071X<br \/>\nIECEx BAS 16.0003X<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Approved for<\/td>\n<td class=\"subattribute\">[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I<br \/>\nEx nA IIC T4 Gc<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">General information<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Supplementary information<\/td>\n<td>Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Classifications<\/h2>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th>System<\/th>\n<th>Classcode<\/th>\n<\/tr>\n<tr>\n<td>ECLASS 11.0<\/td>\n<td>27210129<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 10.0.1<\/td>\n<td>27210129<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 9.0<\/td>\n<td>27210129<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 8.0<\/td>\n<td>27210190<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 5.1<\/td>\n<td>27210107<\/td>\n<\/tr>\n<tr>\n<td>ETIM 8.0<\/td>\n<td>EC002919<\/td>\n<\/tr>\n<tr>\n<td>ETIM 7.0<\/td>\n<td>EC002919<\/td>\n<\/tr>\n<tr>\n<td>ETIM 6.0<\/td>\n<td>EC002919<\/td>\n<\/tr>\n<tr>\n<td>ETIM 5.0<\/td>\n<td>EC001485<\/td>\n<\/tr>\n<tr>\n<td>UNSPSC 12.1<\/td>\n<td>32101514<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<p class=\"alternative\"><strong>Temperature Converter\u00a0<\/strong><\/p>\n<ul id=\"productfeatures\">\n<li>1-channel isolated barrier<\/li>\n<li>24 V DC supply (bus powered)<\/li>\n<li>Thermocouple, RTD, potentiometer or voltage input<\/li>\n<li>Linearized output 4 mA &#8230; 20 mA, sink\/source<\/li>\n<li>Sensor breakage detection<\/li>\n<li>Configurable by PACTware<\/li>\n<li>Line fault detection (LFD)<\/li>\n<li>Up to SIL 2 acc.\u00a0to\u00a0IEC\u00a061508\/IEC\u00a061511<\/li>\n<\/ul>\n","protected":false},"featured_media":1956,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[1258,101,102],"product_tag":[1191,1259],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.6.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Temperature Converter HiC2081 - \u0110\u1ea1i l\u00fd Pepperl Fuchs Vi\u1ec7t Nam<\/title>\n<meta name=\"description\" content=\"Temperature Converter HiC2081 \u00b7 1-channel isolated barrier \u00b7 24 V DC supply (bus powered) \u00b7 Thermocouple, RTD..... Zalo: 0965.130.856\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/newskyvn.com\/product\/hic2081\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Temperature Converter HiC2081 - \u0110\u1ea1i l\u00fd Pepperl Fuchs Vi\u1ec7t Nam\" \/>\n<meta property=\"og:description\" content=\"Temperature Converter HiC2081 \u00b7 1-channel isolated barrier \u00b7 24 V DC supply (bus powered) \u00b7 Thermocouple, RTD..... Zalo: 0965.130.856\" \/>\n<meta property=\"og:url\" content=\"https:\/\/newskyvn.com\/product\/hic2081\/\" \/>\n<meta property=\"og:site_name\" content=\"NEW SKY CO.,LTD\" \/>\n<meta property=\"article:modified_time\" content=\"2024-11-09T09:37:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/b239710a.png\" \/>\n\t<meta property=\"og:image:width\" content=\"455\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/newskyvn.com\/#website\",\"url\":\"https:\/\/newskyvn.com\/\",\"name\":\"NEW SKY CO.,LTD\",\"description\":\"C\\u00f4ng Ty TNHH S\\u1ea3n Xu\\u1ea5t Th\\u01b0\\u01a1ng M\\u1ea1i D\\u1ecbch V\\u1ee5 T\\u00e2n Thi\\u00ean\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/newskyvn.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/newskyvn.com\/product\/hic2081\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/b239710a.png\",\"contentUrl\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/b239710a.png\",\"width\":455,\"height\":500},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/newskyvn.com\/product\/hic2081\/#webpage\",\"url\":\"https:\/\/newskyvn.com\/product\/hic2081\/\",\"name\":\"Temperature Converter HiC2081 - \\u0110\\u1ea1i l\\u00fd Pepperl Fuchs Vi\\u1ec7t Nam\",\"isPartOf\":{\"@id\":\"https:\/\/newskyvn.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/newskyvn.com\/product\/hic2081\/#primaryimage\"},\"datePublished\":\"2021-09-29T09:38:17+00:00\",\"dateModified\":\"2024-11-09T09:37:17+00:00\",\"description\":\"Temperature Converter HiC2081 \\u00b7 1-channel isolated barrier \\u00b7 24 V DC supply (bus powered) \\u00b7 Thermocouple, RTD..... Zalo: 0965.130.856\",\"breadcrumb\":{\"@id\":\"https:\/\/newskyvn.com\/product\/hic2081\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/newskyvn.com\/product\/hic2081\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/newskyvn.com\/product\/hic2081\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Product\",\"item\":\"https:\/\/newskyvn.com\/en\/san-pham\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HiC2081\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product\/1954"}],"collection":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/comments?post=1954"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media\/1956"}],"wp:attachment":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media?parent=1954"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_cat?post=1954"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_tag?post=1954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}