{"id":1948,"date":"2021-09-29T09:25:25","date_gmt":"2021-09-29T09:25:25","guid":{"rendered":"https:\/\/newskyvn.com\/?post_type=product&#038;p=1948"},"modified":"2024-11-09T10:45:46","modified_gmt":"2024-11-09T10:45:46","slug":"hic2025es","status":"publish","type":"product","link":"https:\/\/newskyvn.com\/en\/product\/hic2025es\/","title":{"rendered":"HiC2025ES"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><span style=\"color: #0000ff;\"><strong>TECHNICAL DATA OF HiC2025ES<\/strong><\/span><\/p>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th colspan=\"3\">General specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Signal type<\/td>\n<td>Analog input<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Functional safety related parameters<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safety Integrity Level (SIL)<\/td>\n<td>SIL 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Systematic capability (SC)<\/td>\n<td>SC 3<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Supply<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL1: 1a(-), 1b(-); 2a(+), 2b(+)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated voltage<\/td>\n<td>19 &#8230; 30 V DC bus powered via Termination Board<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ripple<\/td>\n<td>\u2264 10 %<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated current<\/td>\n<td>\u2264 50 mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power dissipation<\/td>\n<td>\u2264 800 mW<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power consumption<\/td>\n<td>\u2264 1.2 W<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Input<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection side<\/td>\n<td>field side<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL2: 5a(+), 1b(-); 5a(+), 5b(-)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Input signal<\/td>\n<td>4 &#8230; 20 mA , limited to approx. 27 mA reverse polarity protected<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Line fault detection<\/td>\n<td>downscaling \u2264 3 mA ; upscaling \u2265 22 mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Voltage drop<\/td>\n<td>approx. 5 V on SL2: 5a(+), 1b(-)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Available voltage<\/td>\n<td>\u2265 15 V at 20 mA on SL2: 5a(+), 5b(-)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection side<\/td>\n<td>control side<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL1: 8a(+), 7a(-)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Load<\/td>\n<td>0 &#8230; 300 \u03a9 (source mode)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output signal<\/td>\n<td>4 &#8230; 20 mA or 1 &#8230; 5 V (on 250 \u03a9, 0.1 % internal shunt)<br \/>\n4 &#8230; 20 mA (sink mode), operating voltage 16 &#8230; 28 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ripple<\/td>\n<td>20 mV\u00a0<sub>rms<\/sub><\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Fault indication output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL1: 6b<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output type<\/td>\n<td>open collector transistor (internal fault bus)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Transfer characteristics<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Deviation<\/td>\n<td>at 20 \u00b0C (68 \u00b0F)<br \/>\n\u2264 \u00b1 20 \u00b5A incl. calibration, linearity, hysteresis, loads and supply voltage fluctuations (source mode and sink mode 4 &#8230; 20 mA)<br \/>\n\u2264 10 mV incl. calibration, linearity, hysteresis and fluctuations of supply voltage (source mode 1 &#8230; 5 V)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Influence of ambient temperature<\/td>\n<td class=\"subattribute\">&lt; 2 \u00b5A\/K (0 &#8230; 70 \u00b0C (32 &#8230; 158 \u00b0F)); &lt; 4 \u00b5A\/K (-20 &#8230; 0 \u00b0C (-4 &#8230; 32 \u00b0F)) (source mode and sink mode 4 &#8230; 20 mA)<br \/>\n&lt; 0.5 mV\/K (0 &#8230; 70 \u00b0C (32 &#8230; 158 \u00b0F)); &lt; 1 mV\/K (-20 &#8230; 0 \u00b0C (-4 &#8230; 32 \u00b0F)) (source mode 1 &#8230; 5 V)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Frequency range<\/td>\n<td>field side into the control side: bandwidth with 1 mA<sub>pp<\/sub>\u00a0signal 0 &#8230; 3 kHz (-3 dB)<br \/>\ncontrol side into the field side: bandwidth with 0.5 V<sub>pp<\/sub>\u00a0signal 0 &#8230; 3 kHz (-3 dB)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Settling time<\/td>\n<td>\u2264 200 ms<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rise time\/fall time<\/td>\n<td>\u2264 20 ms<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Galvanic isolation<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Input\/Output<\/td>\n<td>safe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Input\/power supply<\/td>\n<td>safe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output\/power supply<\/td>\n<td>Basic isolation acc. to EN 61010-1 rated insulation voltage \u2264 50 V<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Indicators\/settings<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Display elements<\/td>\n<td>LEDs<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Control elements<\/td>\n<td>DIP-switch<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Configuration<\/td>\n<td>via DIP switches<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Labeling<\/td>\n<td>space for labeling at the front<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Directive conformity<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Electromagnetic compatibility<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Directive 2014\/30\/EU<\/td>\n<td class=\"subattribute\">EN 61326-1:2013 (industrial locations)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Conformity<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Electromagnetic compatibility<\/td>\n<td>NE 21:2017<br \/>\nFor further information see system description.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Degree of protection<\/td>\n<td>IEC 60529:2001<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Ambient conditions<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient temperature<\/td>\n<td>-20 &#8230; 70 \u00b0C (-4 &#8230; 158 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Mechanical specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Degree of protection<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mass<\/td>\n<td>approx. 100 g<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Dimensions<\/td>\n<td>12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 inch)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mounting<\/td>\n<td>on Termination Board<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Coding<\/td>\n<td>pin 1 and 3 trimmed<br \/>\nFor further information see system description.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Data for application in connection with hazardous areas<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">EU-type examination certificate<\/td>\n<td>CESI 10 ATEX 063<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Marking<\/td>\n<td class=\"subattribute\"><img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II (1)G [Ex ia Ga] IIC<br \/>\n<img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II (1)D [Ex ia Da] IIIC<br \/>\n<img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0I (M1) [Ex ia Ma] I<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Input<\/td>\n<td class=\"subattribute\">Ex ia<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Supply<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Maximum safe voltage<\/td>\n<td class=\"subattribute\">253 V AC (Attention! U<sub>m<\/sub>\u00a0is no rated voltage.)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Equipment<\/td>\n<td>SL2: 5a(+), 5b(-)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Voltage\u00a0U<sub>o<\/sub><\/td>\n<td class=\"subattribute\">25.2 V<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Current\u00a0I<sub>o<\/sub><\/td>\n<td class=\"subattribute\">100 mA<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Power\u00a0P<sub>o<\/sub><\/td>\n<td class=\"subattribute\">630 mW<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Internal capacitance\u00a0C<sub>i<\/sub><\/td>\n<td class=\"subattribute\">5.7 nF<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Internal inductance\u00a0L<sub>i<\/sub><\/td>\n<td class=\"subattribute\">negligible<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Equipment<\/td>\n<td>SL2: 5a(+), 1b(-)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Voltage\u00a0U<sub>i<\/sub><\/td>\n<td class=\"subattribute\">&lt; 30 V<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Current\u00a0I<sub>i<\/sub><\/td>\n<td class=\"subattribute\">&lt; 128 mA<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Voltage\u00a0U<sub>o<\/sub><\/td>\n<td class=\"subattribute\">7.2 V<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Current\u00a0I<sub>o<\/sub><\/td>\n<td class=\"subattribute\">100 mA<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Power\u00a0P<sub>o<\/sub><\/td>\n<td class=\"subattribute\">25 mW<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Internal capacitance\u00a0C<sub>i<\/sub><\/td>\n<td class=\"subattribute\">5.7 nF<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Internal inductance\u00a0L<sub>i<\/sub><\/td>\n<td class=\"subattribute\">negligible<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Certificate<\/td>\n<td>CESI 19 ATEX 016 X<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Marking<\/td>\n<td class=\"subattribute\"><img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II 3G Ex ec IIC T4 Gc<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Directive conformity<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Directive 2014\/34\/EU<\/td>\n<td class=\"subattribute\">EN 60079-0:2012+A11:2013 , EN\u00a060079-11:2012 , EN 60079-7:2015<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">International approvals<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">UL approval<\/td>\n<td>E106378<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Control drawing<\/td>\n<td class=\"subattribute\">116-0376 (cULus)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">IECEx approval<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>IECEx certificate<\/td>\n<td class=\"subattribute\">IECEx CES 10.0021X<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>IECEx marking<\/td>\n<td class=\"subattribute\">[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I<br \/>\nEx ec IIC T4 Gc<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">General information<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Supplementary information<\/td>\n<td>Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Classifications<\/h2>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th>System<\/th>\n<th>Classcode<\/th>\n<\/tr>\n<tr>\n<td>ECLASS 11.0<\/td>\n<td>27210119<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 10.0.1<\/td>\n<td>27210119<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 9.0<\/td>\n<td>27210119<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 8.0<\/td>\n<td>27210119<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 5.1<\/td>\n<td>27210119<\/td>\n<\/tr>\n<tr>\n<td>ETIM 8.0<\/td>\n<td>EC001485<\/td>\n<\/tr>\n<tr>\n<td>ETIM 7.0<\/td>\n<td>EC001485<\/td>\n<\/tr>\n<tr>\n<td>ETIM 6.0<\/td>\n<td>EC001485<\/td>\n<\/tr>\n<tr>\n<td>ETIM 5.0<\/td>\n<td>EC001485<\/td>\n<\/tr>\n<tr>\n<td>UNSPSC 12.1<\/td>\n<td>32101514<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<p class=\"alternative\"><strong>SMART Transmitter Power Supply\u00a0<\/strong><\/p>\n<ul id=\"productfeatures\">\n<li>1-channel isolated barrier<\/li>\n<li>24 V DC supply (bus powered)<\/li>\n<li>Input for 2-wire SMART transmitters and current sources<\/li>\n<li>Output for 4 mA &#8230; 20 mA or 1 V &#8230; 5 V<\/li>\n<li>Sink or source mode<\/li>\n<li>Line fault detection (LFD)<\/li>\n<li>Up to SIL 3 acc.\u00a0to\u00a0IEC\u00a061508<\/li>\n<\/ul>\n","protected":false},"featured_media":1950,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[101,102],"product_tag":[1191,1261],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.6.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SMART Transmitter Power Supply HiC2025ES - \u0110\u1ea1i l\u00fd Pepperl Fuchs<\/title>\n<meta name=\"description\" content=\"SMART Transmitter Power Supply HiC2025ES \u00b7 1-channel isolated barrier \u00b7 24 V DC supply (bus powered) \u00b7 Input for 2-wire..... 0965.130.856\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/newskyvn.com\/product\/hic2025es\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SMART Transmitter Power Supply HiC2025ES - \u0110\u1ea1i l\u00fd Pepperl Fuchs\" \/>\n<meta property=\"og:description\" content=\"SMART Transmitter Power Supply HiC2025ES \u00b7 1-channel isolated barrier \u00b7 24 V DC supply (bus powered) \u00b7 Input for 2-wire..... 0965.130.856\" \/>\n<meta property=\"og:url\" content=\"https:\/\/newskyvn.com\/product\/hic2025es\/\" \/>\n<meta property=\"og:site_name\" content=\"NEW SKY CO.,LTD\" \/>\n<meta property=\"article:modified_time\" content=\"2024-11-09T10:45:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/b231086b.png\" \/>\n\t<meta property=\"og:image:width\" content=\"455\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/newskyvn.com\/#website\",\"url\":\"https:\/\/newskyvn.com\/\",\"name\":\"NEW SKY CO.,LTD\",\"description\":\"C\\u00f4ng Ty TNHH S\\u1ea3n Xu\\u1ea5t Th\\u01b0\\u01a1ng M\\u1ea1i D\\u1ecbch V\\u1ee5 T\\u00e2n Thi\\u00ean\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/newskyvn.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/newskyvn.com\/product\/hic2025es\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/b231086b.png\",\"contentUrl\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/b231086b.png\",\"width\":455,\"height\":500},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/newskyvn.com\/product\/hic2025es\/#webpage\",\"url\":\"https:\/\/newskyvn.com\/product\/hic2025es\/\",\"name\":\"SMART Transmitter Power Supply HiC2025ES - \\u0110\\u1ea1i l\\u00fd Pepperl Fuchs\",\"isPartOf\":{\"@id\":\"https:\/\/newskyvn.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/newskyvn.com\/product\/hic2025es\/#primaryimage\"},\"datePublished\":\"2021-09-29T09:25:25+00:00\",\"dateModified\":\"2024-11-09T10:45:46+00:00\",\"description\":\"SMART Transmitter Power Supply HiC2025ES \\u00b7 1-channel isolated barrier \\u00b7 24 V DC supply (bus powered) \\u00b7 Input for 2-wire..... 0965.130.856\",\"breadcrumb\":{\"@id\":\"https:\/\/newskyvn.com\/product\/hic2025es\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/newskyvn.com\/product\/hic2025es\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/newskyvn.com\/product\/hic2025es\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Product\",\"item\":\"https:\/\/newskyvn.com\/en\/san-pham\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HiC2025ES\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product\/1948"}],"collection":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/comments?post=1948"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media\/1950"}],"wp:attachment":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media?parent=1948"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_cat?post=1948"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_tag?post=1948"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}