{"id":1942,"date":"2021-09-29T09:13:11","date_gmt":"2021-09-29T09:13:11","guid":{"rendered":"https:\/\/newskyvn.com\/?post_type=product&#038;p=1942"},"modified":"2023-05-25T02:14:51","modified_gmt":"2023-05-25T02:14:51","slug":"hid2872","status":"publish","type":"product","link":"https:\/\/newskyvn.com\/en\/product\/hid2872\/","title":{"rendered":"HiD2872"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><span style=\"color: #0000ff;\"><strong>TECHNICAL DATA OF HiD2872<\/strong><\/span><\/p>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th colspan=\"3\">General specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Signal type<\/td>\n<td>Digital Output<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Functional safety related parameters<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safety Integrity Level (SIL)<\/td>\n<td>SIL 3<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Supply<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL1: 1a(-), 1b(-); 2a(+), 2b(+)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated voltage<\/td>\n<td>20.4 &#8230; 30 V DC loop powered<br \/>\n20.4 &#8230; 30 V DC bus powered via Termination Board<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Input current<\/td>\n<td>62 mA at 24 V, 300 \u03a9 load (per channel)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power dissipation<\/td>\n<td>1 W at 24 V, 300 \u03a9 load (per channel)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Input<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection side<\/td>\n<td>control side<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL1: 8a(+), 7a(-); 10a(+), 9a(-) bus powered<br \/>\nSL1: 8b(+), 7b(-); 9b(+), 10b(-) loop powered<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Control input<\/td>\n<td>external switch (dry contact or open collector) non isolated or logic signal input fully floating<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Signal level<\/td>\n<td>1-signal: 15&#8230;30 V DC (current limited at 3 mA) or contact close (internal 10 k\u03a9 pull-up)<br \/>\n0-signal: 0&#8230;5 V DC or contact open<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power dissipation<\/td>\n<td>1 W at 24 V, 300 \u03a9 load (per channel) for loop powered<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Inrush current<\/td>\n<td>0.2 A , 15 ms loop powered<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection side<\/td>\n<td>field side<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL2: 5a(+), 5b(-), 7a(+); 1a(+), 1b(-), 3b(+)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Internal resistor<\/td>\n<td>approx. 240 \u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Current<\/td>\n<td>\u2264 40 mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Voltage<\/td>\n<td>\u2265 12 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Current limit<\/td>\n<td>55 mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Open loop voltage<\/td>\n<td>approx. 22.5 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Load<\/td>\n<td>nominal 0.1 &#8230; 5 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching frequency<\/td>\n<td>&#8211; bus powered: filter OFF: max. 150 Hz, filter ON: max. 15 Hz<br \/>\n&#8211; loop powered: max. 10 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Energized\/De-energized delay<\/td>\n<td>&#8211; bus powered: filter OFF: 1 ms, filter ON: 10 ms<br \/>\n&#8211; loop powered: switch-on 50 ms, switch-off 6 ms (300 \u03a9 load)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Fault indication output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection<\/td>\n<td>SL1: 6b<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output type<\/td>\n<td>open collector transistor (internal fault bus)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Fault current<\/td>\n<td>4 mA pulsing (20 ms ON, 200 ms OFF)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Fault level<\/td>\n<td>lead short-circuit detection at &lt; 25 \u03a9<br \/>\nlead breakage detection at &gt; 100 k\u03a9 typical<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Galvanic isolation<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output\/Output<\/td>\n<td>safe electrical isolation acc. to EN 60079-11: 2007, voltage peak value 60 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output\/power supply, inputs, and collective error<\/td>\n<td>safe electrical isolation acc. to EN 60079-11: 2007, voltage peak value 375 V<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Indicators\/settings<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Display elements<\/td>\n<td>LEDs<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Control elements<\/td>\n<td>DIP-switch<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Configuration<\/td>\n<td>via DIP switches<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Labeling<\/td>\n<td>space for labeling at the front<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Directive conformity<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Electromagnetic compatibility<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Directive 2014\/30\/EU<\/td>\n<td class=\"subattribute\">EN 61326-1:2013 (industrial locations)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Conformity<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Electromagnetic compatibility<\/td>\n<td>NE 21:2006<br \/>\nFor further information see system description.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Degree of protection<\/td>\n<td>IEC 60529:2001<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Ambient conditions<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient temperature<\/td>\n<td>-20 &#8230; 60 \u00b0C (-4 &#8230; 140 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Relative humidity<\/td>\n<td>5 &#8230; 90 %, non-condensing up to 35 \u00b0C (95 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Mechanical specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Degree of protection<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mass<\/td>\n<td>approx. 140 g<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Dimensions<\/td>\n<td>18 x 106 x 128 mm (0.7 x 4.2 x 5 inch)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mounting<\/td>\n<td>on Termination Board<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Coding<\/td>\n<td>pin 1 and 4 trimmed<br \/>\nFor further information see system description.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Data for application in connection with hazardous areas<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">EU-type examination certificate<\/td>\n<td>CESI 10 ATEX 036<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Marking<\/td>\n<td class=\"subattribute\"><img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II (1)G [Ex ia Ga] IIC<br \/>\n<img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II (1)D [Ex ia Da] IIIC<br \/>\n<img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0I (M1) [Ex ia Ma] I<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Output<\/td>\n<td class=\"subattribute\">Ex ia Ga, Ex ia Da, Ex ia Ma<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Voltage<\/td>\n<td class=\"subattribute\">26 V<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Current<\/td>\n<td class=\"subattribute\">110 mA<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Power<\/td>\n<td class=\"subattribute\">715 mW<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Supply<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Maximum safe voltage<\/td>\n<td class=\"subattribute\">253 V AC (Attention! U<sub>m<\/sub>\u00a0is no rated voltage.)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Certificate<\/td>\n<td>PF 10 CERT 1729 X<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Marking<\/td>\n<td class=\"subattribute\"><img src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" \/>\u00a0II 3G Ex nA IIC T4 Gc<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Directive conformity<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Directive 2014\/34\/EU<\/td>\n<td class=\"subattribute\">EN 60079-0:2012+A11:2013 , EN\u00a060079-11:2012 , EN 60079-15:2010<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">International approvals<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">CSA approval<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Control drawing<\/td>\n<td class=\"subattribute\">366-005CS-12B (cCSAus)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">IECEx approval<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>IECEx certificate<\/td>\n<td class=\"subattribute\">IECEx CES 10.0013<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>IECEx marking<\/td>\n<td class=\"subattribute\">[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">General information<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Supplementary information<\/td>\n<td>Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Classifications<\/h2>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th>System<\/th>\n<th>Classcode<\/th>\n<\/tr>\n<tr>\n<td>ECLASS 11.0<\/td>\n<td>27210190<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 10.0.1<\/td>\n<td>27210190<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 9.0<\/td>\n<td>27210190<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 8.0<\/td>\n<td>27210190<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 5.1<\/td>\n<td>27210121<\/td>\n<\/tr>\n<tr>\n<td>ETIM 8.0<\/td>\n<td>EC001485<\/td>\n<\/tr>\n<tr>\n<td>ETIM 7.0<\/td>\n<td>EC001485<\/td>\n<\/tr>\n<tr>\n<td>ETIM 6.0<\/td>\n<td>EC001485<\/td>\n<\/tr>\n<tr>\n<td>ETIM 5.0<\/td>\n<td>EC001485<\/td>\n<\/tr>\n<tr>\n<td>UNSPSC 12.1<\/td>\n<td>39121008<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<p class=\"alternative\"><strong>Solenoid Driver\u00a0<\/strong><\/p>\n<ul id=\"productfeatures\">\n<li>2-channel isolated barrier<\/li>\n<li>24 V DC supply (bus or loop powered)<\/li>\n<li>Output 40 mA at 12 V DC, 55 mA current limit<\/li>\n<li>Contact or logic control input<\/li>\n<li>Entity parameter I<sub>o<\/sub>\/I<sub>sc<\/sub>\u00a0= 110 mA<\/li>\n<li>Line fault detection (LFD)<\/li>\n<li>Up to SIL 2 acc.\u00a0to\u00a0IEC\u00a061508 (bus powered)<\/li>\n<li>Up to SIL 3 acc.\u00a0to\u00a0IEC\u00a061508 (loop powered)<\/li>\n<\/ul>\n","protected":false},"featured_media":1944,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[101,102],"product_tag":[1191,1263],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.6.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Solenoid Driver HiD2872 - \u0110\u1ea1i l\u00fd Pepperl fuchs - 0965.130.856<\/title>\n<meta name=\"description\" content=\"Solenoid Driver HiD2872 \u00b7 2-channel isolated barrier \u00b7 24 V DC supply (bus or loop powered) \u00b7 Output 40 mA at 12 V DC, 55 mA current limit..\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/newskyvn.com\/product\/hid2872\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Solenoid Driver HiD2872 - \u0110\u1ea1i l\u00fd Pepperl fuchs - 0965.130.856\" \/>\n<meta property=\"og:description\" content=\"Solenoid Driver HiD2872 \u00b7 2-channel isolated barrier \u00b7 24 V DC supply (bus or loop powered) \u00b7 Output 40 mA at 12 V DC, 55 mA current limit..\" \/>\n<meta property=\"og:url\" content=\"https:\/\/newskyvn.com\/product\/hid2872\/\" \/>\n<meta property=\"og:site_name\" content=\"NEW SKY CO.,LTD\" \/>\n<meta property=\"article:modified_time\" content=\"2023-05-25T02:14:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/b234921a.png\" \/>\n\t<meta property=\"og:image:width\" content=\"455\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/newskyvn.com\/#website\",\"url\":\"https:\/\/newskyvn.com\/\",\"name\":\"NEW SKY CO.,LTD\",\"description\":\"C\\u00f4ng Ty TNHH S\\u1ea3n Xu\\u1ea5t Th\\u01b0\\u01a1ng M\\u1ea1i D\\u1ecbch V\\u1ee5 T\\u00e2n Thi\\u00ean\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/newskyvn.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/newskyvn.com\/product\/hid2872\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/b234921a.png\",\"contentUrl\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/b234921a.png\",\"width\":455,\"height\":500},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/newskyvn.com\/product\/hid2872\/#webpage\",\"url\":\"https:\/\/newskyvn.com\/product\/hid2872\/\",\"name\":\"Solenoid Driver HiD2872 - \\u0110\\u1ea1i l\\u00fd Pepperl fuchs - 0965.130.856\",\"isPartOf\":{\"@id\":\"https:\/\/newskyvn.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/newskyvn.com\/product\/hid2872\/#primaryimage\"},\"datePublished\":\"2021-09-29T09:13:11+00:00\",\"dateModified\":\"2023-05-25T02:14:51+00:00\",\"description\":\"Solenoid Driver HiD2872 \\u00b7 2-channel isolated barrier \\u00b7 24 V DC supply (bus or loop powered) \\u00b7 Output 40 mA at 12 V DC, 55 mA current limit..\",\"breadcrumb\":{\"@id\":\"https:\/\/newskyvn.com\/product\/hid2872\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/newskyvn.com\/product\/hid2872\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/newskyvn.com\/product\/hid2872\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Product\",\"item\":\"https:\/\/newskyvn.com\/en\/san-pham\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HiD2872\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product\/1942"}],"collection":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/comments?post=1942"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media\/1944"}],"wp:attachment":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media?parent=1942"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_cat?post=1942"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_tag?post=1942"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}