{"id":1148,"date":"2021-09-16T02:44:26","date_gmt":"2021-09-16T02:44:26","guid":{"rendered":"https:\/\/newskyvn.com\/?post_type=product&#038;p=1148"},"modified":"2021-09-16T02:44:27","modified_gmt":"2021-09-16T02:44:27","slug":"pmi120-f90-iu2ep-io-v15","status":"publish","type":"product","link":"https:\/\/newskyvn.com\/en\/product\/pmi120-f90-iu2ep-io-v15\/","title":{"rendered":"PMI120-F90-IU2EP-IO-V15"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p id=\"techdata\"><strong><span style=\"color: #0000ff;\">excerpt: Technical data of\u00a0 PMI120-F90-IU2EP-IO-V15<\/span><\/strong><\/p>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th colspan=\"3\">General specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching element function<\/td>\n<td>Analog current or voltage output, programmable<br \/>\n2 switch outputs, programmable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Object distance<\/td>\n<td>0.5 &#8230; 3 mm , recommended: 1.5 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Measurement range<\/td>\n<td>0 &#8230; 120 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Linearity range<\/td>\n<td>1 &#8230; 119 mm<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Nominal ratings<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating voltage<\/td>\n<td>12 &#8230; 30 V DC<br \/>\n(13 &#8230; 30 V when analog voltage output is parameterized)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Reverse polarity protection<\/td>\n<td>reverse polarity protected<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Linearity error<\/td>\n<td>within measuring range: \u00b1 0.8 mm<br \/>\nwithin linearity range: \u00b1 0.4 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Repeat accuracy<\/td>\n<td>\u00b1 0.1 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Resolution<\/td>\n<td>50 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Temperature drift<\/td>\n<td>\u00b1 0.5 mm (-25 \u00b0C &#8230; 70 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">No-load supply current<\/td>\n<td>\u2264 40 mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating voltage indicator<\/td>\n<td>LED green<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Functional safety related parameters<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">MTTF<sub>d<\/sub><\/td>\n<td>271 a<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mission Time (T<sub>M<\/sub>)<\/td>\n<td>20 a<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Diagnostic Coverage (DC)<\/td>\n<td>0 %<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Indicators\/operating means<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">LED S1<\/td>\n<td>switching state Switching output 1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">LED S2<\/td>\n<td>switching state Switching output 2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">LED S3<\/td>\n<td>Damping element in the configured analog measuring range<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">LED STATUS<\/td>\n<td>Status display LED, green\/red (Power on, communication\/error, missing damping element)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Interface<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Interface type<\/td>\n<td>IO-Link (via C\/Q = Pin 4)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Device profile<\/td>\n<td>Smart Sensor<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Device ID<\/td>\n<td>0x200403 (2098179)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Transfer rate<\/td>\n<td>COM\u00a02 (38.4 kBaud)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Value range<\/td>\n<td>0000h &#8230; 9600h<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Min. cycle time<\/td>\n<td>2.3 ms<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Process data width<\/td>\n<td>Process data input: 16 Bit<br \/>\nProcess data output: none<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">SIO mode support<\/td>\n<td>yes<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Compatible master port type<\/td>\n<td>A<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Switching output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output type<\/td>\n<td>2 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection, surge-proof<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating current<\/td>\n<td>\u2264 100 mA \/ output<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching window<\/td>\n<td>\u00b1 1 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Switching hysteresis<\/td>\n<td>0.2 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Voltage drop<\/td>\n<td>\u2264 3 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Short-circuit protection<\/td>\n<td>pulsing<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Analog output<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output type<\/td>\n<td>1 current output: 4 &#8230; 20 mA or 1 voltage output: 0 &#8230; 10 V , programmable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Load resistor<\/td>\n<td>current output: \u2264 400 \u03a9<br \/>\nvoltage output: \u2265 1000 \u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Short-circuit protection<\/td>\n<td>voltage output: current limit<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Compliance with standards and directives<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Standard conformity<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Standards<\/td>\n<td class=\"subattribute\">EN 60947-5-2:2007<br \/>\nEN 60947-5-2\/A1:2012<br \/>\nIEC 60947-5-2:2007<br \/>\nIEC 60947-5-2 AMD 1:2012<br \/>\nEN 60947-5-7:2003<br \/>\nEN61131-9:2013<br \/>\nIEC 60947-5-7:2003<br \/>\nIEC 61131-9:2013<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Approvals and certificates<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">UL approval<\/td>\n<td>cULus Listed, Class 2 Power Source, Type 1 enclosure<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Marine approval<\/td>\n<td>DNVGL TAA00001V2<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Ambient conditions<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Ambient temperature<\/td>\n<td>-25 &#8230; 85 \u00b0C (-13 &#8230; 185 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"3\">Mechanical specifications<\/th>\n<\/tr>\n<tr>\n<td colspan=\"2\">Connection type<\/td>\n<td>5-pin, M12 x 1 connector<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Degree of protection<\/td>\n<td>IP67 \/ IP69K<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Material<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Housing<\/td>\n<td class=\"subattribute\">PBT, stainless steel 1.4571 , brass, nickel-plated<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Target<\/td>\n<td class=\"subattribute\">mild steel, e. g. 1.0037, SR235JR (formerly St37-2)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mass<\/td>\n<td>113 g<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><span style=\"color: #0000ff;\">Classifications<\/span><\/strong><\/p>\n<table class=\"standard enum\">\n<tbody>\n<tr>\n<th>System<\/th>\n<th>Classcode<\/th>\n<\/tr>\n<tr>\n<td>ECLASS 11.0<\/td>\n<td>27270702<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 10.0.1<\/td>\n<td>27270702<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 9.0<\/td>\n<td>27270702<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 8.0<\/td>\n<td>27270702<\/td>\n<\/tr>\n<tr>\n<td>ECLASS 5.1<\/td>\n<td>27270702<\/td>\n<\/tr>\n<tr>\n<td>ETIM 8.0<\/td>\n<td>EC001852<\/td>\n<\/tr>\n<tr>\n<td>ETIM 7.0<\/td>\n<td>EC001852<\/td>\n<\/tr>\n<tr>\n<td>ETIM 6.0<\/td>\n<td>EC001852<\/td>\n<\/tr>\n<tr>\n<td>ETIM 5.0<\/td>\n<td>EC001852<\/td>\n<\/tr>\n<tr>\n<td>UNSPSC 12.1<\/td>\n<td>39121550<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<ul id=\"productfeatures\">\n<li>Parameterization and diagnosis via IO-Link<\/li>\n<li>Measuring range 0 &#8230; 120 mm<\/li>\n<li>Parameterisable measuring range<\/li>\n<li>Analog current or voltage output, programmable<\/li>\n<li>2 Push-pull outputs<\/li>\n<li>Switch points programmable via IO-Link<\/li>\n<\/ul>\n","protected":false},"featured_media":1151,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[31,56],"product_tag":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.6.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>PMI120-F90-IU2EP-IO-V15 - NEW SKY CO.,LTD<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/newskyvn.com\/product\/pmi120-f90-iu2ep-io-v15\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PMI120-F90-IU2EP-IO-V15 - NEW SKY CO.,LTD\" \/>\n<meta property=\"og:description\" content=\"[:vi]  Tham s\u1ed1 h\u00f3a v\u00e0 k\u1ebft n\u1ed1i d\u1eef li\u1ec7u chu\u1ea9n IO-Link  Ph\u1ea1m vi \u0111o 0 ... 120 mm  D\u1ea3i \u0111o c\u00f3 th\u1ec3 tham s\u1ed1  \u0110\u1ea7u ra d\u00f2ng \u0111i\u1ec7n ho\u1eb7c \u0111i\u1ec7n \u00e1p t\u01b0\u01a1ng t\u1ef1, c\u00f3 th\u1ec3 l\u1eadp tr\u00ecnh  2 \u0111\u1ea7u ra Push-Pull  Chuy\u1ec3n \u0111\u1ed5i \u0111i\u1ec3m c\u00f3 th\u1ec3 l\u1eadp tr\u00ecnh qua IO-Link [:en]  Parameterization and diagnosis via IO-Link  Measuring range 0 ... 120 mm  Parameterisable measuring range  Analog current or voltage output, programmable  2 Push-pull outputs  Switch points programmable via IO-Link [:]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/newskyvn.com\/product\/pmi120-f90-iu2ep-io-v15\/\" \/>\n<meta property=\"og:site_name\" content=\"NEW SKY CO.,LTD\" \/>\n<meta property=\"article:modified_time\" content=\"2021-09-16T02:44:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/pmi120.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/newskyvn.com\/#website\",\"url\":\"https:\/\/newskyvn.com\/\",\"name\":\"NEW SKY CO.,LTD\",\"description\":\"C\\u00f4ng Ty TNHH S\\u1ea3n Xu\\u1ea5t Th\\u01b0\\u01a1ng M\\u1ea1i D\\u1ecbch V\\u1ee5 T\\u00e2n Thi\\u00ean\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/newskyvn.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/newskyvn.com\/product\/pmi120-f90-iu2ep-io-v15\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/pmi120.jpg\",\"contentUrl\":\"https:\/\/newskyvn.com\/wp-content\/uploads\/2021\/09\/pmi120.jpg\",\"width\":500,\"height\":500},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/newskyvn.com\/product\/pmi120-f90-iu2ep-io-v15\/#webpage\",\"url\":\"https:\/\/newskyvn.com\/product\/pmi120-f90-iu2ep-io-v15\/\",\"name\":\"PMI120-F90-IU2EP-IO-V15 - NEW SKY CO.,LTD\",\"isPartOf\":{\"@id\":\"https:\/\/newskyvn.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/newskyvn.com\/product\/pmi120-f90-iu2ep-io-v15\/#primaryimage\"},\"datePublished\":\"2021-09-16T02:44:26+00:00\",\"dateModified\":\"2021-09-16T02:44:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/newskyvn.com\/product\/pmi120-f90-iu2ep-io-v15\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/newskyvn.com\/product\/pmi120-f90-iu2ep-io-v15\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/newskyvn.com\/product\/pmi120-f90-iu2ep-io-v15\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Product\",\"item\":\"https:\/\/newskyvn.com\/en\/san-pham\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PMI120-F90-IU2EP-IO-V15\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product\/1148"}],"collection":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/comments?post=1148"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media\/1151"}],"wp:attachment":[{"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/media?parent=1148"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_cat?post=1148"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/newskyvn.com\/en\/wp-json\/wp\/v2\/product_tag?post=1148"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}